S
U
V
V
U
S
4
3
2
1
6
5
59
8-CONNECTIONS TO ADDITIONAL DEVICES
Technical Dept. - All rights reserved - Reproduction prohibited
Comfort Air ducting
Comfort Air stoves can channel the air into other rooms through the connection with the accessory pipes to the rear “S” shaped flange
provided as per standard. The recommended maximum duct length is 8 metres per fan. It is advisable to set up ducts of similar length to
distribute the hot air evenly in the various rooms.
The outlet air pipe can reach very high temperatures, even around 150°C: therefore, it must be adequately insulated
with suitable material, especially points that could come in contact with flammable surfaces or parts that are
affected by heat (e.g. change in shades, wiring ducts, plasterboard, etc.). Moreover, persons and animals must be
protected from accidental or intentional contact. In any case, comply with the regulations and laws in force in the
region where the product is installed.
It is recommended to insulate the entire length of the pipe in order to reduce dispersion and increase heat output
in the room.
If you do not wish to channel the air, the hot air may be let out through the rear “V” vent without connecting any pipe.
The “V” vent and the “U” clamp used for fastening are found in a plastic bag inside the hopper of the stove.
1 - ROOM FLOOR
2 - ROOM CEILING
3 - WALL
4 - STOVE
5 - HOT AIR DUCTING
6 - INSULATION