29
3-DRAWINGS AND TECHNICAL SPECIFICATIONS
Technical Dept. - All rights reserved - Reproduction prohibited
EN
Manufacturer:
MCZ GROUP SpA
Trademak:
MCZ
Model Identifier:
Indirect heating functionality:
NO
no
Direct heat output (space heat output):
10,0
kW
Indirect heat output (water heat output):
kW
CPR harmonised standard:
EN 14785:2006
Notified Body:
ACTECO SRL (N.B. 1880)
Via Amman 41, 33084 Cordenons (PN), IT
Fuel
ηs [%]
EEI [%]
Log wood, moisture content ≤ 25 %
no
Compressed wood with moisture content < 12 %
yes
79,2
120
Other woody biomass
A+
(A++ / G scale)
Characteristics when operating with the preferred fuel:
CO
NO
x
OGC
PM
35
141
2
18
534
125
5
14
##
Symbol
Value
Unit
0
NO
P
nom
10,0
kW
1
NO
P
min
2,3
kW
2
NO
4
NO
η
th,nom
90,4
%
6
NO
η
th,min
92,6
%
7
YES
1
el
max
0,062
kW
room temperature control, with presence detection
NO
el
min
0,040
kW
room temperature control, with open window detection
NO
el
sb
0,004
kW
1
with distance control option
YES
1
EN
INFORMATION REQUIREMENTS FOR SOLID FUEL LOCAL SPACE HEATERS
ACCORDING TO COMMISSION REGULATIONS (EU) 2015/1185 - (EU) 2015/1186 (PRODUCT FICHE)
Observe the specific precautions for installation, assembly and maintenance indicated in the manual accompanying the product, and the national and
local rules in force
Product description:
Type of heat output/room temperature control (select one)
Other suitable fuel(s):
Preferred fuel:
NO
YES
NO
Mechanically fed roomheater burning wood pellets
MUSA AIR 10 UP! M2
NO
NO
NO
Auxiliary electricity consumption
with mechanic thermostat room temperature control
Energy Efficiency Class
Item
Minimum heat output (indicative)
Heat output
In standby mode
Nominal heat output
At nominal heat output
At minimum heat output
Space heating emissions (mg/Nm3 at 13% O2)
at Nominal heat output
at Minimum heat output
Useful efficiency at nominal heat
output
with electronic room temperature control
with electronic room temperature control plus day timer
with electronic room temperature control plus week timer
two or more manual stages, no room temperature control
Useful efficiency (NCV as received)
Useful efficiency at minimum heat
output (indicative)
single stage heat output, no room temperature control
Other control options (multiple selections possible)