Chimneypot
The chimneypot, meaning the end part of the flue, must meet the following characteristics:
•
the smoke outlet section must be at least double the internal section of the chimney;
•
prevent the penetration of rain or snow;
•
ensure the outlet of smoke even in the event of wind (windproof chimneypot);
•
the height of outflow must be beyond the reflux area (*) (refer to national regulations to identify the reflux area);
•
always be built at a distance from antennas or dishes, and never be used as a support.
(*) unless there are specific national derogations (clearly specified in the corresponding instruction manual in English) which under
appropriate conditions allow it; in this case, strictly follow the product/installation requirements of the relative regulations/technical
specifications/legislation in force in that country.