Table 10, AGZ 035A - 065A, 60 Hz, Compressor and Condenser Fan Motor Amp Draw
Rated Load Amps
Locked Rotor Amps
Compressors
Compressors
Across-The-Line
AGZ
Unit
Size
Volts
No.
1 & 3
(Each)
No.
2 & 4
(Each)
Fan
Motors
(Each)
No. Of
Fan
Motors
Fan
Motors
(Each)
No.1 & 3
(Each)
No.2 & 4
(Each)
208
30.5
30.5
4.0
4
17.0
232
232
230
30.5
30.5
4.0
4
17.0
232
232
380
18.6
18.6
3.4
4
14.4
144
144
460
15.8
15.8
2.0
4
8.5
125
125
035A
575
11.6
11.6
2.2
4
10.3
100
100
208
35.2
35.2
4.0
4
17.0
278
278
230
35.2
35.2
4.0
4
17.0
278
278
380
22.8
22.8
3.4
4
14.4
151
151
460
16.5
16.5
2.0
4
8.5
127
127
040A
575
13.7
13.7
2.2
4
10.3
100
100
208
35.2
41.5
5.8
4
23.7
278
350
230
35.2
41.5
5.8
4
23.7
278
350
380
22.8
28.0
3.4
4
14.4
151
195
460
16.5
21.8
2.8
4
10.7
127
158
045A
575
13.7
17.3
2.3
4
11.5
100
125
208
41.5
41.5
5.8
4
23.7
350
350
230
41.5
41.5
5.8
4
23.7
350
350
380
28.0
28.0
3.4
4
14.4
195
195
460
21.8
21.8
2.8
4
10.7
158
158
050A
575
17.3
17.3
2.3
4
11.5
125
125
208
41.5
52.8
5.8
4
23.7
350
425
230
41.5
52.8
5.8
4
23.7
350
425
380
28.0
32.7
3.4
4
14.4
195
239
460
21.8
23.7
2.8
4
10.7
158
187
055A
575
17.3
22.1
2.3
4
11.5
125
148
208
52.8
52.8
5.8
4
23.7
425
425
230
52.8
52.8
5.8
4
23.7
425
425
380
32.7
32.7
3.4
4
14.4
239
239
460
23.7
23.7
2.8
4
10.7
187
187
060A
575
22.1
22.1
2.3
4
11.5
148
148
208
52.8
52.8
5.8
4
23.7
425
425
230
52.8
52.8
5.8
4
23.7
425
425
380
32.7
32.7
3.4
4
14.4
239
239
460
23.7
23.7
2.8
4
10.7
187
187
065A
575
22.1
22.1
2.3
4
11.5
148
148
Table 11, AGZ035A - 065A, 60 Hz Single Point Power, Field Wiring Data
Wiring to Standard
Power Block
Wiring to Optional
Non-Fused Disconnect Switch
AGZ
Unit
Size
Volts
Terminal
Amps
Connector Wire Range
(Copper Wire Only)
Terminal
Amps
Connector Wire Range
(Copper Wire Only)
208
335
# 4 - 400 MCM
225
#4 – 4/0
230
335
# 4 - 400 MCM
225
#4 – 4/0
380
175
#12 - 2/0
100
#14 - 1/0
460
175
#12 - 2/0
100
#14 - 1/0
035A
575
175
#12 - 2/0
100
#14 - 1/0
208
335
# 4 - 400 MCM
225
#4 – 4/0
230
335
# 4 - 400 MCM
225
#4 – 4/0
380
175
#12 - 2/0
150
#4 – 4/0
460
175
#12 - 2/0
100
#14 - 1/0
040A
575
175
#12 - 2/0
100
#14 - 1/0
208
335
# 4 - 400 MCM
225
#4 – 4/0
230
335
# 4 - 400 MCM
225
#4 – 4/0
380
175
#12 - 2/0
150
#4 – 4/0
460
175
#12 - 2/0
100
#14 - 1/0
045A
575
175
#12 - 2/0
100
#14 - 1/0
Table continued on next page
Summary of Contents for AGZ 035A
Page 6: ...6 AGZ 035A through 065A IOMM AGZ 3 Figure 3 Clearance Requirements...
Page 18: ...18 AGZ 035A through 065A IOMM AGZ 3 Electrical Legend Figure 8 Electrical Legend...
Page 19: ...IOMM AGZ 3 AGZ 035A through 065A 19 Figure 9 Typical Field Wiring with Global UNT Controller...
Page 21: ...IOMM AGZ 3 AGZ 035A through 065A 21 Figure 11 Single point Connection with FanTrol...
Page 22: ...22 AGZ 035A through 065A IOMM AGZ 3 Figure 12 Single point Connection with SpeedTrol...
Page 23: ...IOMM AGZ 3 AGZ 035A through 065A 23 Figure 13 Unit Control Schematic UNT...
Page 24: ...24 AGZ 035A through 065A IOMM AGZ 3 Figure 14 Staging Schematic UNT...
Page 25: ...IOMM AGZ 3 AGZ 035A through 065A 25 Figure 15 MicroTech Controller Schematic...
Page 26: ...26 AGZ 035A through 065A IOMM AGZ 3 Figure 16 Unit Control Schematic MicroTech...
Page 27: ...IOMM AGZ 3 AGZ 035A through 065A 27 Figure 17 Staging Schematic MicroTech...
Page 94: ...94 AGZ 035A through 065A IOMM AGZ 3 Notes...
Page 95: ......