User Manual
MCOHome Technology Co., Ltd 2015
5
Press “
M
” again will enter interface for Key-touch volume (BEEP) setting:
0 : Off
1: Low(default)
2: High
Temp. Sensor Error
If temperature sensor does not work, “E1” displays , fan stops and valve closes automatically.
Z-Wave Operation
Including & Excluding of Z-Wave network
Under the shutdown state, press & hold
to enter interface for inclusion or exclusion of
Z-Wave network. Before device included into network, “- - -” will display on the screen. Then
press
once, device will enter learning mode to get a node ID. If inclusion is success, a node
ID will display on the screen in a few seconds.
A node ID can always inform us whether the device is in the network or not.
Note: Follow the same steps to exclude the device from the network.
After inclusion, turn off the device and then turn it on. Now the device is ready to be
operated by controller/ gateway in Z-Wave network.
Association Group
Thermostat supports 1 association group. A gateway is suggested to associate with this
group. Then if any changes happen, such as: temperature, working mode, fan state etc., the
thermostat will report to this associated device (gateway). When the detected temperature change
≥
0.5
℃
, device will send unsolicited report to the gateway.
Command Class supported by the device:
COMMAND_CLASS_BASIC;
COMMAND_CLASS_THERMOSTAT_SETPOINT;
COMMAND_CLASS_THERMOSTAT_MODE;
COMMAND_CLASS_THERMOSTAT_FAN_MODE;
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE;
COMMAND_CLASS_SENSOR_MULTILEVEL;
COMMAND_CLASS_ASSOCIATION;
COMMAND_CLASS_VERSION;
COMMAND_CLASS_MANUFACTURER_SPECIFIC