- 6 -
Receiver (RX)
Active Frequencies
38 kHz
: 38 kHz
±
2%
9.5 kHz
: 9.5 kHz
±
2%
80 kHz
: 80 kHz
±
2%
512Hz
: 512 Hz
±
2%
LF
: Low frequency(200Hz to 1000Hz) --- factory configurable
Passive Radio
RAD
: 9 k to 33 kHz (80 bands)
Passive Power
POW
: 45~65 Hz
120 Hz
: 95~125 Hz
Battery type
Six Alkaline LR6 “AA”
Battery Life
18 hours (20
°
C / 68
°
F)
Battery Status
Continuous indication
Power save function
Automatically power off after 5minutes of inactivity
Visual Indication
LCD : Bar graph , Digital number & character, include Backlight
Depth Display Range
High precision depth measurement
Line: 0 to 5 m /16 ft. ( 0-5 m / 0-16 ft. mode)
0 to 10 m /30 ft. (0-10 m / 0-30 ft. mode)
Probe : 0 to 10 m /30 ft.
Real time depth measurement
0 to 9.9 m / 33ft.
Depth Readout Unit
Meter / Feet & Inch
Depth Accuracy*
1
2.0m / 6.5ft. :
±
2.5%
3.0m / 10ft. :
±
5%
5.0m / 16.5ft. :
±
10%
Current value
Current value flowing on the conductor is displayed for line identity in
milliamps.
Audio output
Internal Speaker with sound volume adjusting function, Earphone
(optional)
Data logging
Memorized 400 points of the depth/ the current measurement/ the date and
time data.
Interface
6-pin output connector
Operating Temperature
-20
°
C to 50
°
C / -4
°
F to 122
°
F
Dimensions
660 x 130 x 270 mm (26.0" x 5.1" x 10.6")
Weight
2.1 kg/ 4.7 lbs. approx. including six batteries
Note: *1 Locators are tested in test field conditions with no adjacent signals.
Always excavate the line with non-destructive means before digging.
*2 Optional cable is necessary to read the logging data.
Summary of Contents for Vision GX2