- 16 -
Direct Connection mode
Use the Receiver 5m / 16ft. away from the
transmitter and clips.
Applications (1)
Applications (2)
If the dead cable is the object, connect the red alligator clip of the connecting cable to either the aluminum-sheath
or a bundle of the copper cores directly.
5m / 16ft. away
Telephone cable:
Disconnect Telephone
Ground lead and connect
the Red clip to it to locate
Telephone line.
CATV cable:
Disconnect CATV's
ground lead and connect
the Red clip to it to locate
CATV line.
Telephone cable
CATV cable
Remember to correctly reconnect common grounds for telephone & CATV.
Check Local codes for proper grounding procedure. IMPROPER GROUNDING MAY CAUSE
DAMAGE TO APPLIANCES, FIRE OR EXPLOSIONS.
WARNING
The ground should be provide at
the end of the line
Short distance dead cable
Long distance dead cable
No need of ground at the ending point
Common ground lead
Power cable
House meter
Power cable:
Disconnect other utilities that maybe
connected to the common ground lead
and connect the Red clip to Power line
ground lead. Then locate Power line.
WARNING
Do not disconnect
power line
Summary of Contents for Vision GX2