- 12 -
*
Messages during your search procedure :
Receiving signal is too high.
a) Indirect mode : Transmitter and Receiver are too close each other.
b) Other options: Reduce output of the Transmitter.
Receiving signal is too weak or not present.
a) In the case of direct, induction or coil
- Increase output of the Transmitter.
- Check batteries, connecting parts and frequency of the Transmitter.
- Check signal loop at the Transmitter.
b) In the case of Radio / Power mode
- There are no conductors to radiate magnetic fields. There is no pipe or cable
- There is a conductor, but the signal is too low to adhere to the line. Use Transmitter
to search for the line.
*
Messages on location :
Press
GAIN
key.
Þ
Normally this is your object line.
Reduces or increases signal strength.
*
Messages on Depth measurement :
a) Received signal level is unstable, or received signal is too weak.
b) Located point is not directly above the object line.
c) Metallic fences, metallic structures or cars are interfering with the depth
measurement. Find area with less interference.
d) The Line is disconnected.
Indicating that the depth measured is deeper than 5 m / 16 ft.
In Line detection (0-5m / 0-16ft.) mode, locator cannot read below this depth
*
Messages on transmitting operation:
Inside temperature exceeded an upper limit.
Þ
Power off and move the transmitter to the cool place.
Power electric current exceeded an upper limit.
Inside temperature exceeded an upper limit.
Þ
Leave the transmitter from the neighborhood of the metal.
Decrease transmitting output.
6. Warning Message
OVER
LOW
PUSH
GAIN
ERR
16. --ft/in.
5. --m
HEAT!
LIMIT
Summary of Contents for Vision GX2