7

 

When doing the cable fault location work, the cable locating is possible. 

 
When being connected A-FRAME, the cable locating is possible with switching the 
mode to Cable locating mode. 
 
 
Press  

 Peak/Null 

  . 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Move to the direction of the arrow and measure the location of the cable. 
 
 
 
 
 
 
 
 
 
 
 
 
When going back to Fault finding mode, press  

 Peak/Null 

  again. 

 
 
 
 
 
 
 

The direction of 
the object line.

 

Receiving level 

No bar-graph

 

Yaw angle

 

Real time depth

 

Operational frequency 
or 
Real time Current 

Fault finding mode

 

30 

150 

40 

550 

Move in the direction 
of the arrow.

  

100 

340 

300 

Cable locating mode

 

OUT OF RANGE 

Number of receiving 
level is blinked. 

Object line 

Summary of Contents for VISION FLX2

Page 1: ...VISION FLX2 MANUAL AUG 22 2016 833 083...

Page 2: ...direction of the cable path Connect the black end of the direct connection cables to the ground stake Connect the red end of the direct connection cables on the cable to be checked Power on Press Fre...

Page 3: ...he direct connection cables to the ground stake Connect the red end of the direct connection cables on the cable to be checked Power on Press Frequency and select FF Press ADJUST Resistance is indicat...

Page 4: ...cable Press and hold the Gain Select key for one second this will adjust the sensitivity of the Receiver and display 70 0 If the Receiver displays OVER manually reduce the output on the Transmitter u...

Page 5: ...e A frame in the earth every five to ten feet Note If LCD does not display arrow or signal strength A frame is not reading signal The A frame may not be making contact with earth or signal is too weak...

Page 6: ...point will be in the center of the A frame CONFIRM THE FAULT LOCATION Turn the A frame 90 degrees perpendicular to the cable path Place the A frame in the earth and follow the direction the arrows ar...

Page 7: ...he red leg Multiple Faults Place both legs of the A frame in the ground with the red leg directly over the fault point With a line that has multiple faults the fault that registers the highest reading...

Page 8: ...rection of the arrow and measure the location of the cable When going back to Fault finding mode press Peak Null again The direction of the object line Receiving level No bar graph Yaw angle Real time...

Reviews: