3
RECEIVER
Connect the A-frame to the
Receiver.
Place both legs of the A-frame in the earth with the red leg pointing at the ground stake.
Distance from ground stake should be approximately the same as the suspected depth of
the cable.
Press and hold the
Gain/Select
key for one second, this will adjust the sensitivity of
the Receiver and display 70.0% +/-
If the Receiver displays
OVER
– manually reduce the output on the Transmitter until
overload message is replaced with numbers.
Note: This will be a reference number if line has multiple faults.
Ground
Stake
Meter
Transformer
Cable Path
Transmitter
Same as depth
of the cable
Gain/Select
.
A-frame
A-frame
Fault