background image

 

3

RECEIVER 

Connect the A-frame to the

 

Receiver. 

 
 
 
 
 
 
 
 
 
Place both legs of the A-frame in the earth with the red leg pointing at the ground stake. 
Distance from ground stake should be approximately the same as the suspected depth of 
the cable.  
 
 
 
 
 
 
 
 
 
 
 
 
 
Press and hold the 

 Gain/Select  

key for one second, this will adjust the sensitivity of 

the Receiver and display 70.0% +/-  
If the Receiver displays 

OVER

– manually reduce the output on the Transmitter until 

overload message is replaced with numbers.  
 
 
 
Note: This will be a reference number if line has multiple faults.   
 
 
 
 
 
 
 
 
 
 
 

Ground            
 Stake    

 

  

Meter

 

Transformer

 

Cable Path 

Transmitter

 

Same as depth 
of the cable 

 

 

Gain/Select

  

.

 

A-frame

 

A-frame

 

Fault 

Summary of Contents for VISION FLX2

Page 1: ...VISION FLX2 MANUAL AUG 22 2016 833 083...

Page 2: ...direction of the cable path Connect the black end of the direct connection cables to the ground stake Connect the red end of the direct connection cables on the cable to be checked Power on Press Fre...

Page 3: ...he direct connection cables to the ground stake Connect the red end of the direct connection cables on the cable to be checked Power on Press Frequency and select FF Press ADJUST Resistance is indicat...

Page 4: ...cable Press and hold the Gain Select key for one second this will adjust the sensitivity of the Receiver and display 70 0 If the Receiver displays OVER manually reduce the output on the Transmitter u...

Page 5: ...e A frame in the earth every five to ten feet Note If LCD does not display arrow or signal strength A frame is not reading signal The A frame may not be making contact with earth or signal is too weak...

Page 6: ...point will be in the center of the A frame CONFIRM THE FAULT LOCATION Turn the A frame 90 degrees perpendicular to the cable path Place the A frame in the earth and follow the direction the arrows ar...

Page 7: ...he red leg Multiple Faults Place both legs of the A frame in the ground with the red leg directly over the fault point With a line that has multiple faults the fault that registers the highest reading...

Page 8: ...rection of the arrow and measure the location of the cable When going back to Fault finding mode press Peak Null again The direction of the object line Receiving level No bar graph Yaw angle Real time...