background image

41

Messages

Display

Reason

Action

Invalid 

Hematocrit

Repeat with new test strip, using 

capillary whole blood from the 

finger or forearm or venous whole 

blood collected with sodium 

heparin, lithium heparin or EDTA. 

If error persists, call for assistance.

Temperature 

Error

Too Cold/ 

Too Hot

Move meter and test strips 

to area between 41°F-104°F; 

wait 10 minutes for System 

to reach room temperature 

before testing.

Sample Not 

Detected or 

Using Wrong 

Test Strip

Retest with new 

McKesson TRUE METRIX® 

PRO Professional 

Monitoring Blood Glucose 

Test Strip and larger sample.

Used Test Strip, 

Test Strip out-

side of vial too 

long, Sample on 

top of Test Strip.

Repeat with new test 

strip.  Make sure sample 

is touched to edge of test 

strip (not top). If error 

persists, call for assistance.

Meter

Error

Call for

assistance.

Summary of Contents for TRUE METRIX PRO

Page 1: ...re Professional Having most blood glucose results within the patient s target range shows how well a treatment plan is working to control glucose levels Keeping results within the patient s target ran...

Page 2: ...betes mellitus or for measuring blood glucose in newborns ONLY use auto disabling single use lancing devices lancets to obtain capillary blood sample Alternative site forearm testing should not be use...

Page 3: ...e Reuse of test strips will cause inaccurate results NEVER add a second drop of sample to test strip Adding more sample gives an error message Perform Control Tests before performing a blood glucose t...

Page 4: ...o obtain capillary blood For more information on standard precautions and practices please refer to http www cdc gov hicpac 2007ip 2007isolationprecautions html Multiple patient use devices such as bl...

Page 5: ...ess or trouble speaking High blood glucose hyperglycemia symptoms may include intense thirst a need to urinate often a dry mouth vomiting or headache This device has not been validated for use in the...

Page 6: ...e 19 How to Test Blood 22 TRUE METRIX PRO Meter and Laboratory Testing 25 System Out of Range Warning Messages 26 Meter Set Up Set Time and Date 27 Set Event Tags Ketone Test Alert and Test Reminders...

Page 7: ...hrough Event Tags to mark results if feature on Button Turn meter on to view Average values to view results in Memory to access Meter Set Up and turn on Event Tags in Meter Memory Button Decrease numb...

Page 8: ...up Strip Release Button Releases test strip after testing for disposal Battery Door Use one non rechargeable 3V lithium battery CR2032 positive side up see Changing Battery Meter Label Contains serial...

Page 9: ...r 30 day Average 6 Test Result 7 Control Symbol 8 Battery Symbol 9 Alternate Site ALT Symbol 10 Drop Symbol Apply blood or control solution 11 Temperature Symbol 12 Test Reminder Symbol 13 Ketone Test...

Page 10: ...ip to blood or control solution drop Sample Placement Correct Incorrect Allow sample drop to be drawn into Sample Tip until testing begins meter beeps and dashes move across Display Do not smear or sc...

Page 11: ...or date printed next to EXP on vial label has passed whichever comes first Caution Use of test strips or control solution past the Expiration Dates may give incorrect test results Discard out of date...

Page 12: ...of control solution Call 1 800 803 6025 for assistance in obtaining different levels of control solution For use only with McKesson TRUE METRIX and TRUE METRIX PRO Blood Glucose Test Strips Not inten...

Page 13: ...erted correctly into the Test Port Insert a test strip into the Test Port The meter is working properly if the full Display appears then the time appears in the upper part of the Display and then the...

Page 14: ...or cold or humidity Whenever a check on the performance of the system is needed If meter damage is suspected meter was dropped crushed wet etc Note It is important to perform Control Tests with more...

Page 15: ...hs after first opening or date next to EXP on label test strips 4 months after first opening or date next to EXP on labels Discard expired products and use new products 2 Allow control solution vial o...

Page 16: ...n meter until testing is nished Note If Strip is removed before testing is nished an error message appears Release and discard old test strip Use new test strip for testing 7 With cap removed turn con...

Page 17: ...of control solution you are using If result is in range system can be used for testing blood If result does not fall within range repeat test using a new test strip Note Control Test result shows the...

Page 18: ...er result is shown Strip Release Button ashes Hold meter with test strip pointing down Press Strip Release Button to release and discard test strip into appropriate container Meter turns off Note Remo...

Page 19: ...andards Institute CLSI M29 A3 Venous whole blood collected only in sodium heparin tubes may be used for testing Mix well before use DO NOT use sodium fluoride grey top vacutainer tubes This may cause...

Page 20: ...ry thoroughly 2 Lance finger 3 To help blood drop form lower the hand to a level below the heart and gently massage the finger from palm to fingertip Allow the blood drop to form before attempting to...

Page 21: ...falling rapidly or their results often fluctuate If the patient is ill or under stress If the glucose result may be low or high If symptoms of low or high glucose levels are not evident 1 Select area...

Page 22: ...l from vial 4 With meter off insert test strip Contact End blocks facing up into Test Port Meter turns on Keep test strip in meter until testing is nished To mark test as alternate site forearm result...

Page 23: ...ediately after the meter beeps and dashes appear across the meter Display Note If meter does not begin testing soon after touching Sample Tip to drop discard test strip Repeat test with new test strip...

Page 24: ...ard materials into appropriate container Wash hands after taking off gloves Note Removing test strip before result displays cancels the test An error message appears and result is not stored in Memory...

Page 25: ...enous whole blood collected in sodium fluoride grey top lithium heparin or EDTA vacutainer tubes for testing as this may cause inaccurate results When comparing results between McKesson TRUE METRIX PR...

Page 26: ...Note Lo results are included in the Average as 20 mg dL Hi results are included as 600 mg dL If blood glucose test result is greater than 240 mg dL and Ketone Test Alert is turned on Ketone appears in...

Page 27: ...ck to Step 1 under Meter Set Up and begin again 1 Press and hold Button until the full Display is shown and a tone sounds about 10 seconds Release Button Meter goes into Set Up Set Time Date 2 The hou...

Page 28: ...month Press Button to set 5 The day number ashes To change press or Button to select the day Press Button to set 6 The year ashes To change press or Button to select the year Press Button to set Note...

Page 29: ...press or Button to turn Event Tags on or off Press Button to set The meter goes to set Ketone Test Alert Top of Meter Event Tags may be used after each blood glucose result Event Tags are as follows B...

Page 30: ...octor or diabetes healthcare professional 2 Press or Button to turn Alert on or off Press Button to set Meter goes to set Test Reminder Caution When a Ketone Test Alert sounds it does not mean that ke...

Page 31: ...etting A 1 To turn Reminder on press Button Press Button to turn Reminder back to off Press Button to set Meter goes to the next Test Reminder 2 When on is chosen press Button The hour ashes Press or...

Page 32: ...next 3 Reminders if needed Exit Set Up Press and hold Button until meter turns off Meter also turns off after 2 minutes of non use Set up choices are saved Note If Test Reminders are set the Alert Sym...

Page 33: ...the average of all blood glucose results performed on the meter within a 7 14 or 30 day period Control Test results are not included in the Averages 1 With meter off press and release Button Display...

Page 34: ...2 Press Button and release to advance to the most recent blood test Press Button to scroll forward through results or Button to scroll backwards through results Test results marked as alternate site...

Page 35: ...d dirt Store at temperature range of 40 86 F 4 30 C DO NOT FREEZE Allow System to sit at room temperature for 10 minutes before testing Meter Care Cleaning and Disinfecting Cleaning removes blood and...

Page 36: ...ing motions with moderate pressure on the front back left side right side top and bottom of the meter Repeat as needed until all surfaces are visibly clean Discard used wipes Environmental Protection...

Page 37: ...utomatic Self Test gives an error message For general questions about McKesson TRUE METRIX PRO products call 1 800 777 4908 For additional assistance call 1 800 803 6025 Note Other disinfectants have...

Page 38: ...ng Blood Glucose Test Strip Care Store test strips in original vial only Do not transfer old test strips to new vial or store test strips outside of vial Write date opened on test strip vial Discard u...

Page 39: ...nsert new battery positive side facing up Close Battery Door Note Use non rechargeable 3V lithium battery CR2032 5 Press Button to turn meter on and check time date and Testing Alerts and Reminders se...

Page 40: ...emove test strip Re insert test strip fully into meter Test strip error Repeat with new test strip Dead or no battery Replace battery Battery in backwards Battery positive side must face up Meter erro...

Page 41: ...test strips to area between 41 F 104 F wait 10 minutes for System to reach room temperature before testing Sample Not Detected or Using Wrong Test Strip Retest with new McKesson TRUE METRIX PRO Profe...

Page 42: ...r persists call for assistance If symptoms such as fatigue excess urination thirst or blurry vision are found follow healthcare professional s advice for high blood glucose Test Strip Removed During T...

Page 43: ...stance Display Reason Action Broken Display Do not use meter for testing For general questions call 1 800 777 4908 For additional assistance call 1 800 803 6025 WARNING Out of Range High Results 600 m...

Page 44: ...atic shut off After two minutes of non use Weight 1 66 ounces Size 3 44 x 2 16 x 0 69 Memory Size 500 glucose results Operating Range meter test strips Relative Humidity 10 90 Non condensing Temperatu...

Page 45: ...y and cause the meter to display false results 4 The duration of any implied Warranty including any implied Warranty of merchantability or tness for a particular purpose shall be limited to the lifeti...

Page 46: ...5 htm 3 CDC Clinical Reminder Use of Fingerstick Devices on More Than One Person Poses Risk for Transmitting Blood borne Pathogens 2010 http www cdc gov injectionsafety Fingerstick DevicesBGM html 4 F...

Page 47: ...47 Notes...

Page 48: ...48 RE4SUNP03 Rev 1 Notes...

Reviews: