McKesson LUMEON 3069 Operation Manual Download Page 14

12

Infrared Tympanic Electronic Thermometer

Regulatory and Safety Standards:         

The Infrared Tympanic Electronic Thermometer follows international regulatory standards.

•  EN 12470-5:2003 (E) Clinical Thermometers – Part 5: Performance of infrared ear thermometers where   

  sections 6.3.4 and 6.5.5 were met based on technical report.  Data is available from Kendall on request.

• UL 60601-1 

• EN 60601-1 

• EN 60601-1-2 

• MDD 93/42/EEC 

• BS EN 980: 2003 

• ASTM E1965-98

• IEC 1000-4-2: 1995 

• IEC 1000-4-3:1995

The device meets EN12470-5:2003 (E) and ASTM E1965-98 subject to the following conditions:

1.  The software was modified during testing to increase the precision of the measurements taken from one  

 

 

significant digit to two significant digits.

2.  The increased precision numbers were then averaged to account for the known variance in measurements  

 

taken due to human factors.

Section XII —  Customer Service 

In the event that it is necessary to return a unit for repair, please contact PSS World Medical customer information 

desk at 

 800-777-4908.

Parts Listing

To order repair parts, contact our customer service center or your sales representative for the parts listed below.

Description 

 

 

 

 

 

 

 

 

    Order Part Number

Infrared Tympanic Electronic Thermometer Probe Covers  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3068
Infrared Tympanic Electronic Thermometer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3069

Section XIII — Warranty

LIMITED WARRANTY:  

 Your Lumeon™ electronic thermometer is manufactured exclusively for PSS World 

Medical by Kendall, a Tyco Healthcare Group LP company. Kendall warrants to the original purchaser (“Customer”) 

that this product will be free of defects in materials and workmanship, under normal use, for one (1) year from the 

date of original purchase from PSS World Medical.  If this product does not operate as warranted above during 

the applicable warranty period, Kendall may, at its option and expense, replace the defective part or product, or, 

if neither replacement nor repair is reasonably available, refund to Customer the purchase price for the defective 

part or product.  Dated proof of original purchase will be required.

Summary of Contents for LUMEON 3069

Page 1: ...n Scale Dimensions Revisions Rev Description Date K PMS 110Yellow Meghan Little 3069_Masterpage Tympanic Thermometers 1 1 Proportion As Provided Final Final Draft 09 03 09 PMS 110Yellow K INFRARED TYM...

Page 2: ...5 Temperature Display Toggle 5 Sleep Mode 5 Pulse Timer Mode 6 Thermometer Display Icons and Alarms 6 Biotech Mode 7 Section VI Preventative Maintenance 9 Section VII Cleaning 9 Section VIII Battery...

Page 3: ...Features Very fast temperature acquisition that meets CEN and ASTM standards see Section XI Peak Select System Temperature measurement range of 33 0 C to 42 0 C 91 4 F to 107 6 F Once temperature has...

Page 4: ...mperatures during cold weather conditions allow the patient to equilibrate to room temperature before use Excessive eardrum scarring may cause lowered temperature readings Under normal conditions ear...

Page 5: ...Thermometer probe covers could jeopardize the accuracy of the Infrared Tympanic Electronic Thermometer Check your probe cover carton for the LumeonTM logo to be certain that your thermometer will deli...

Page 6: ...PSS World Medical Inc will result in erroneous temperature measurement In order to aid in infection prevention and control always install a new probe cover prior to taking a temperature The probe cov...

Page 7: ...age Temperature Recall After a temperature has been acquired the thermometer will enter off mode after approximately 10 seconds Recall the temperature by pressing and releasing the scan button or by p...

Page 8: ...talled or the batteries have been changed the thermometer will perform a system reset The thermometer will perform an internal test to verify that the system components are functioning properly Alarm...

Page 9: ...ory calibration parameters are also stored in nonvolatile memory The factory default settings are shown below Temperature mode C unlocked Site mode Ear Site text On The biotech mode is accessed by pre...

Page 10: ...8 Infrared Tympanic Electronic Thermometer Temperature mode Option Display C unlocked Locked C Locked F F unlocked C C F F Site mode Option Display Oral Core Axillary Rectal Ear ORL CORE AX REC EAR...

Page 11: ...and or smudges for proper operation A mild detergent may be added to the water Do not use cleaners such as Spray Nine Phisohex Hibiclens or Vesta Syde disinfectants as they may result in damage to the...

Page 12: ...meter equilibrate in the room for 20 minutes before using For all other system errors reset the thermometer by installing a probe cover If the system error does not clear send the thermometer to the f...

Page 13: ...ondensing Storage Temperature Range 25 C to 55 C 13 F to 131 F up to 95 RH non condensing If the unit is stored at extremes it is recommended that the unit be checked on the field calibration checker...

Page 14: ...ry to return a unit for repair please contact PSS World Medical customer information desk at 800 777 4908 Parts Listing To order repair parts contact our customer service center or your sales represen...

Page 15: ...abeling Comments or Questions about Lumeon Products 800 777 4908 Manufactured for PSS World Medical Inc 4345 Southpoint Blvd Jacksonville FL 32216 Made in the USA www myselectonline com One or more U...

Reviews: