7.
Remove table safety bar and lower table back down
8.
Test the machine in automatic mode to see if it is stopping correctly, if it is not
re-adjust
11.6 Table load position magnet (991 BE series)
If the table does not start in the correct position, in line with the chassis and with the cut
& hold to the left, it is possible to move the magnet that controls the start position.
Firstly, however, this must be checked first with the machine operating at the correct
speed, having a bale on the table with plastic film attached as all of these factors will
have a bearing on where the machine stops. (See Section 15.1.1 in “Trouble Shooting”
on page 81)
The magnet may be adjusted as follows:
1.
Tip up the table and fit the safety bar
2.
Identify the magnet to be changed. There are two set of magnets near the
outside of the table. The magnets that require adjusting are positioned nearest
the cut & hold.
3.
Loosen the M6 bolt and nyloc nut holding the magnets in position and move as
follows
4.
If the table does not turn far enough, push the magnets in the direction shown
5.
If the table is turning too far, push the magnets in the direction shown
6.
Tighten the M6 bolt and nyloc nut (Do not overtighten as the magnets may
crack or shatter)
7.
Remove the table safety bar and lower the table back down
8.
Test the machine in automatic mode to see if it is stopping correctly, if it is not
readjust
NOTE: BJS machines are to be adjusted manually
For BJS machines the stop position must be manually adjusted before
tipping.
Figure 11.e - Tip up table & fit safety bar
Figure 11.f - Table stop position magnet