6 - 5
Battery Calibration
Battery Level is reported in several screens (the main
menu, and screen #200 Ready to Log Data). In order
for accurate reading, the battery must be calibrated.
Uncallibrated battery readings are preceded by a ‘
?
’
symbol. The battery needs to be calibrated if (a) it was
completely discharged, (b) it was removed from the PC
9800, or (c) a new battery was installed.
The DataLogger
™
program must be running to perform
battery calibration. The calibration could take 20
hours.
Follow these steps to calibrate the PC 9800 battery:
1) Plug in the AC adapter and turn on the PC 9800.
2) From the Main Menu, press <3> for System Menu
3) In the System Menu, press <5> to Calibrate Battery
4) Type 123 and press <Enter> for password.
5) The PC 9800 screen should read BATTERY
MANAGER V1.42 at the top, and the screen font is
reduced in size.
6) This process will take 20 hours. (However, you may
abort it any time by pressing the BLUE key followed by
the <I> key to generate an <@>. If you do abort, you
need to press the <Enter> key again to exit the
calibration program and return to the DataLogger
™
program. In addition, if AC power is disrupted during
calibration, the calibration will be aborted, and you
need to manually restart the calibration.)
7) At the end of the calibration, the screen font will be
restored to normal (larger) size, and you need to press
<Enter> to return to the DataLogger
™
program.
8) Press the BLUE key and then the <V> key (
?
key) for
the diagnostics screen. If the calibration was successful,
the third battery status line should read "Calibrated",
and the fourth battery status line should show the
charge and discharge times of the calibration, and the
battery’s capacity.
TX01385-4-15-99
Maintenance and Troubleshooting
Reprogram the DataLogger
™
Follow these steps to update or reprogram the
DataLogger
™
:
1) Locate the DB9 to DB9 Communication Cable.
Connect one end of the cable to the DataLogger
™
,
and the other end to your PC’s serial port.
Remember which PC serial port you are connected
to.
2) Plug in the DataLogger
™
AC adapter to ensure that
power is not interrupted during programming.
3) On the DataLogger
™
, navigate to the System Menu
by pressing <3> in the Main Menu.
4) Press <7> to execute COM.EXE, then press <Y>
when asked “Are you sure you want to run
COM.EXE
?
“
5) You should see the top line of the DataLogger
™
screen read COM Ver 2.46.
6) Insert the DataLogger
™
Program Diskette in Drive A:
of your PC.
7) From the Start button of a your Windows 95/98 or
NT 4.0 PC, choose Run.
8) If you are using COM1 on your PC, type LOAD1
and press <Enter>. If you are using COM2, type
LOAD2 and press <Enter>. There are also LOAD3
and LOAD4 for COM3 and COM4.
9) Once programmed, your PC will close the COM.exe
program automatically. The DataLogger
™
will reboot.
After the reboot, the DataLogger
™
program should be
up and running with the new program.
TX01385-4-15-99