Installation and use
COMPUTER XP805
20
Programming the pressure sensor
programmable range
: 5 ÷ 30
step
: 1
default
: 10
The "Pr" will flash, thereby indicating the maximum value that can be detected
by the pressure sensor used
Programming the density of the product used
programmable range
: 0.50 ÷ 2.00
step
: 0.01
default
:
1.00
The "d" will flash, thereby indicating the density of the product used
Programming the capacity of the tank
programmable range
: 0 ÷ 9999 L
step
: 1
default
: 150
The “t” will flash, thereby indicating the maximum capacity of the tank of the
machine; this data will be used to reload the totaliser
,
and the
dispensed litres will be deducted from this value
Programming of the feed-rate in automatic mode
programmable range
: 1.0 ÷ 9.0
step
: 0.1
default
:
4.0
The “dP” will flash, thereby indicating the speed adjustment coefficient in the
Automatic work mode (see Par.5.4)
Programming the permissible error range
programmable range
: 3 ÷ 20
step
: 1
default
: 20
The “CE” will flash, thereby indicating the permissible error range as a
percentage, referred to the programmed L/Ha value, during the automatic
adjustment
Programming the number of nozzles present
programmable range
: 1 ÷ 100
step
: 1
default
: 20
The “nU” will flash, thereby indicating the total number of nozzles present on
the machine
Programming the flow rate of the nozzle to 2 bar
“U1” programmable range
: 0.10 ÷ 9.99
step
: 0.01
default
: 0.32
“U2” programmable range
: 0.10 ÷ 9.99
step
: 0.01
default
: 0.48
“U3” programmable range
: 0.10 ÷ 9.99
step
: 0.01
default
: 0.65
“U4” programmable range
: 0.10 ÷ 9.99
step
: 0.01
default
: 0.96
“U5” programmable range
: 0.10 ÷ 9.99
step
: 0.01
default
: 1.29
“U6” programmable range
: 0.10 ÷ 9.99
step
: 0.01
default
: 1.61
“U7” programmable range
: 0.10 ÷ 9.99
step
: 0.01
default
: 1.94
“U8” programmable range
: 0.10 ÷ 9.99
step
: 0.01
default
: 2.00
The “U1” indication will flash and the arrow will indicate the corresponding
nozzle; this parameter corresponds to the flow rate in L/min that the nozzle
dispenses with a pressure of 2 bar; this data is very important when working
with the pressure sensor. Pressing the
P
SET/RESET
ROGRAMMING
key allows you to move to the
next nozzle
Then, pressing the
P
SET/RESET
ROGRAMMING
key before exiting and returning to the normal work mode,
the Computer will display the software version currently programmed, as shown in
the figure: