oper3500.doc
Page 15
23/01/2004
7.
COUNTER
The counter can be reset to '0000' by pressing the rectangular black button below the number window.
8.
REPLACING STAPLING HEADS
Should it become necessary to replace either or both of the stapling heads release the heads from the
stapling head retaining plate (part no. 2.73) by loosening the Allen screws. When fitting a replacement
head ensure that the locating dimples on the head are located correctly in the retaining bracket.
9.
ALIGNING OF STAPLING HEADS
Replacement heads should fit into the Bookletmaker without the need for side to side or backwards and
forwards adjustment. However, should this be necessary, such adjustment is obtained as follows:
1.
Loosen the hexagon head nut fixing the retaining plate to the stapling head universal bar (part no.
2.74).
2.
Unlock and pull out the staple cassette.
3.
Insert the stapling head alignment tool from the bottom into the staple output slot with the numbers
facing the front of the machine.
4.
Close and lock the cassette with tool in place.
5.
Push head and tool down and align head until the bottom of the tool fits into and is centred in the
rear slot of the anvil.
6.
Re-tighten hex head nut, re-check alignment and if correct open cassette and remove alignment
tool.
7.
On the face of the cassette there is a vertical guide line. There is also a line on the anvil. Always
ensure that the two are in line.