8
5.
Solar Irradiation Sensor – Connections
Care should be taken so that no components on the PCB are touched.
Terminal numbers on the sensor PCB are given in the picture 5.1 below.
Picture – 5.1: Terminal Numbers of PCB
Connections for the transducer terminals are given in the table 5.1 below.
Terminal MBMet-500AB
MBMet-500BB
MBMet-500CB
MBMet-500DB
1
9-32 V DC +
9-32 V DC +
9-32 V DC +
9-32 V DC +
2
GND
GND
GND
GND
3
RS485 D+
RS485 D+
RS485 D+
RS485 D+
4
RS485 D-
RS485 D-
RS485 D-
RS485 D-
5
NA
Integrated Ambient
Temperature RTD (A)
External Ambient
Temperature RTD (A)
External PV Module
Temperature RTD (A)
6
NA
Integrated Ambient
Temperature RTD (A)
External Ambient
Temperature RTD (A)
External PV Module
Temperature RTD (A)
7
NA
Integrated Ambient
Temperature RTD (B)
External Ambient
Temperature RTD (B)
External PV Module
Temperature RTD (B)
8
NA
Integrated Ambient
Temperature RTD (B)
External Ambient
Temperature RTD (B)
External PV Module
Temperature RTD (B)
Table-5.1: MBMet-500 connections