U s e r M a n U a l
1 6
1 7
• It is essential that the new pool is balanced correctly. Consult your
pool builder on how do this or Maytronics can provide information to
do this.
• You can find the water chemistry parameters on p. 21 of this manual.
Operating Instructions
Salt/ Mineral Requirements
All Ozone Swim units require 3,500-4,500ppm salt/mineral levels.
Using only refined swimming pool salt or minerals, add the desired
quantity to the swimming pool water. To assist in the rapid dissolving and
mixing, sweep or brush the solids until they are fully dissolved.
Note:
Undissolved salt may result in staining of your pool’s interior walls.
Achieving the correct salt/mineral levels
New Pools
Existing Pools
For best results, the salt concentration in the pool water is required to be
within an average range of approximately 3,500 to 4,500ppm. Check salt/
mineral supplier's guide for achieving correct ppm.
To establish the salt level in an existing pool, take a water sample to your
local pool shop for testing, they will tell you the current salt/mineral levels
(TDS) and advise the correct course of action required.
Sanitation Switch
Off
The system will not operate.
Auto
The time clock will automatically switch your pool
equipment on or off at your designated times.
Manual
The timer is by-passed, the system will operate all
functions permanently.
Ozone Swim 1000, 2000 and 3000 series User Manual – JULY 2017 ENG rev 2.0
P a g e
11 | 15
•
Set the timer (see setting the timer) to run for the recommended times (4-6 hours
for winter and 8-10 hours for summer) switch the system to auto and the unit will
now be controlled by the timer
•
To set current time, rotate minute hand clockwise until arrow head aligns with
correct time.
o
Note:
This will need to be reset whenever the power is disconnected from
the unit and for daylight saving time changes.
o
Note:
Only rotate clockwise to set. Rotating incorrectly will damage the time
clock.
•
To set ON/OFF times, move required tappets to appropriate position. Inner position
for OFF and outer position for ON.
o
Note:
proper operation requires that the appropriate switch settings below
are enabled
•
Each of the tappets on outer edge of the timer represents 15-minute intervals.
((N
NO
OTTEE)) IIff yyoouu rreeqquuiirree yyoouurr O
Ozzoonnee SSw
wiim
m ttoo bbee ccoonnnneecctteedd ttoo aann ooffff--ppeeaakk ttaarriiffff w
wee rreeccoom
mm
meenndd tthhee
uussee ooff aann aapppprroopprriiaattee bbaatttteerryy bbaacckkuupp ttiim
mee cclloocckk ffoorr tthhaatt ppuurrppoossee..
CChheecckkiinngg CChhlloorriinnaattiioonn oouuttppuutt
The chlorine cell output controller regulates the amount of chlorine production relevant to
the position it has been set to. By adjusting the cell output controller clockwise, you
increase chlorine production and by turning anti clockwise you reduce production. Do not
attempt to turn the controller beyond its stops as this could cause damage to your unit that
is not covered by warranty.
To ensure your Chlorinator is working correctly, follow the steps below
•
Ensure the cell production is at maximum
•
With the unit running take a sample of water from the skimmer box and conduct a
chlorine test, note the result
•
Take a sample of water from directly in from of the return to the pool outlet and
conduct a chlorine test, note the result
•
If the latter is higher in chlorine than the first test, your ozone Swim is efficiently
producing chlorine (if not please see troubleshooting)
CChheecckkiinngg O
Ozzoonnee oouuttppuutt
To ensure your Ozone is working follow the steps below
•
Check that the green ozone light is on
• Set the master switch to the “on” position.
• Set the sanitation switch to “manual” position to turn the unit on.
• Once the salt/minerals have been added and dissolved turn the
cell production dial to the required position based on the season
and the size of the pool (set to max output to start with and
adjust down as required).
• Set the timer (see setting the timer) to run for the
recommended times (4-6 hours for winter / 8-10 hours for
summer), switch the system to auto and the unit will now be
controlled by the timer.
• To set current time, rotate minute hand clockwise until arrow
head aligns with correct time.
Note:
This will need to be reset whenever the power is
disconnected from the unit and for daylight saving time changes.
Note:
Only rotate clockwise to set. Rotating incorrectly will damage
the time clock.
• To set ON/OFF times, move required tappets to appropriate
position. Inner position for OFF and outer position for ON.
Note:
proper operation requires that the appropriate switch
settings below are enabled.
• Each of the tappets on outer edge of the timer represents
15-minute intervals.
Note:
If you require your Ozone Swim to be connected to an
off-peak tariff we recommend the use of an appropriate battery
backup time clock for that purpose.
Summary of Contents for OzoneSwim 1000
Page 1: ...1200i 1000 2000 3000 USER MANUAL v 1 ...
Page 14: ...ozoneswim com au ...