background image

-3-

FIGURE 3

SLIDE-IN

FIGURE 2

FREE-STANDING

*

When

replacing

an existing unit, a maximum of 23 1/2

²

is acceptable. If the cut depth exceeds 23 1/2

²

, use filler kit (K70 Fill).

30

²

CABINET

OPENING

CAUTION:

SOME WHITE EUROPEAN STYLE CABINETS ARE EQUIPPED WITH DELICATE WHITE VINYL

DRAWER AND DOOR FRONTS. THE VINYL MAY NOT BE DESIGNED TO WITHSTAND THE

HEAT PRODUCED BY THE NORMAL SAFE OPERATION OF A SELF-CLEAN RANGE.

DISCOLORATION OR DELAMINATION MAY OCCUR. TO AVOID POSSIBLE DAMAGE, WE

RECOMMEND INCREASING THE 30

²

CABINET OPENING TO 31 1/4

²

MINIMUM AND USING

HEAT SHIELD KIT-CABKIT V. THE COUNTERTOP CUT-OUT MUST REMAIN 30

²

.

BEFORE ATTEMPTING

INSTALLATION, ADJUST

RANGE LEVELING LEGS

TO ACCOMMODATE

THIS DIMENSION.

36

²

COUNTER

TOP HEIGHT

24

²

CABINET

DEPTH

25

²

MINIMUM

COUNTER

TOP DEPTH

23 5/8

²

MIN.

FLAT

AREA

30

²

5 1/2

²

10

²

5 1/2

²

*23 1/4

²

CUT DEPTH

NOTE:

ON CABINET TOPS WITH

FORMED FRONT EDGE, SHAVE

RAISED SECTION TO CLEAR TOP.

PROVIDE FOR 120/208,

120/240 VOLT OUTLET

PER APPLICABLE

CORD IN THIS AREA.

Summary of Contents for PER5715BAW

Page 1: ...e of range can result in serious injury or property damage CLEARANCE DIMENSIONS For complete information in regard to installation of free standing drop in and slide in ranges see figures 1 through 4...

Page 2: ...L INSPECTOR A 30 inches minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet or A 24 inches minimum when bottom of wood or metal cabinet is p...

Page 3: ...SELF CLEAN RANGE DISCOLORATION OR DELAMINATION MAY OCCUR TO AVOID POSSIBLE DAMAGE WE RECOMMEND INCREASING THE 30 CABINET OPENING TO 31 1 4 MINIMUM AND USING HEAT SHIELD KIT CABKIT V THE COUNTERTOP CU...

Page 4: ...23 1 4 CUT DEPTH PROVIDE FOR 120 208 120 240 VOLT JUNCTION BOX FOR RANGE CONDUIT BELOW UNIT 1 1 4 27 1 2 FROM TOP OF COUNTER 30 CABINET OPENING RECOMMEND THE USE OF 3 1 2 WIDE SLATS ON EACH SIDE 24 C...

Page 5: ...l C Use the bracket as a template and mark the required holes as shown in figure 5 for the type of construction you will be using D Free standing and slide in ranges may be secured to either floor or...

Page 6: ...are equipped with a non lift up top All free standing ranges with a glass top are non lift up Coil tops are lift up D For SAFETY CONSIDERATIONS as well as optimum performance adjust the range so that...

Page 7: ...ire plug in outlet placed at a convenient point near the back of the range The range is then connected to this outlet through an approved range connector pigtail fastened securely to the terminal bloc...

Page 8: ...d Only a 4 wire cord or conduit should be used 2 The ground wire from the service cord or conduit must connect to the range chassis using the green ground screw 3 The white wire of the service cord or...