  OPTIONS TO USE IF SPECIAL PRICING IS SELECTED (continued):

SPECIAL PRICE START HOUR 

NOTE:

 Uses military time – 24 hr. clock.

This is the start hour, 0–23 hours. Select START  

HOUR by pressing the WHITES AND COLORS key 

pad.

g

   Press the PERM. PRESS key pad once to advance to next code.

SPECIAL PRICE STOP HOUR 

NOTE:

 Uses military time – 24 hr. clock.

This is the stop hour; 0–23 hours. Select STOP HOUR 

by pressing the WHITES AND COLORS key pad.

g

   Press the PERM. PRESS key pad once to advance to next code.

SPECIAL PRICE DAY

This represents the day of the week and whether 

special pricing is selected for that day. A number 

followed by “0” indicates no selection that particular 

day (9.10). A number followed by an “S” indicates 

selected for that day (9.1S). 
Days of the week (1–7) can be chosen by pressing the 

WHITES AND COLORS key pad. Press DELICATES  

key pad once to select special pricing for each day 

chosen.
When exiting setup code “9.,” the display must show 

current day of week:
  DISPLAY 

DAY OF WEEK 

CODE (selected)

 

10 

Day 1 = Sunday 

1S

 

20 

Day 2 = Monday 

2S

 

30 

Day 3 = Tuesday 

3S

 

40 

Day 4 = Wednesday 

4S

 

50 

Day 5 = Thursday 

5S

 

60 

Day 6 = Friday 

6S

 

70 

Day 7 = Saturday 

7S

g

   Press the PERM. PRESS key pad once to advance to next code.

7. 0 0 

7. 0 0

 CODE 

EXPLANATION

8. 0 0 

8. 0 0

9. 1 0

9. 1 0

VAULT VIEWING OPTION

This option is either SELECTED “ON” or 

NOT SELECTED “OFF.”
Not Selected “OFF.”
Selected “ON.” Press DELICATES key pad once for 

this selection. When selected, the money and/or cycle 

counts will be viewable (if counting is selected) when 

the coin box is removed.

g

   Press the PERM. PRESS key pad once to advance to next code.

VALUE OF COIN 1

This represents the value of coin 1 in number of 

nickels: 05 = $0.25.
By pressing the WHITES AND COLORS key pad you 

have the option of 1–199 nickels.

g

   Press the PERM. PRESS key pad once to advance to next code.

VALUE OF COIN 2

This represents the value of coin 2 in number of 

nickels: 20 = $1.00.
By pressing the WHITES AND COLORS key pad you 

have the option of 1–199 nickels.
PR MODELS ONLY: For PR models using Enhanced 

Debit, this field represents the value of top off in  

nickels.
PR MODELS: Factory preset for $0.25.

g

   Press the PERM. PRESS key pad once to advance to next code.

A. 0 0 

A. 0 0  

A.S C  

6. 0 5 
6. 0 5   

C. 2 0 
C. 2 0 

 CODE 

EXPLANATION

COIN SLIDE OPTION

This option is either SELECTED “ON” or 

NOT SELECTED “OFF.”
Not Selected “OFF.”
Selected “ON.” 
Press the DELICATES key pad 3 consecutive times 

for this selection. When coin slide mode is selected, 

set “b.” equal to value of slide in nickels. Set “606” 

(REGULAR CYCLE PRICE)  and “3.06” (SPECIAL 

CYCLE PRICE) to number of slide operations. 

NOTE:

 If the installer sets up “CS” on a coin drop 

model, it will not register coins.

g

   Press the PERM. PRESS key pad once to advance to next 

code.

ADD COINS OPTION

This option is either SELECTED “ON” or NOT 

SELECTED “OFF.” This option causes the customer 

display to show the number of coins (coin 1) to enter, 

rather than the dollars-and-cents amount.
Not Selected “OFF.”
Selected “ON.” 
Press the DELICATES keypad 3 consecutive times for 

this selection.
PR MODELS ONLY: In enhanced debit mode, this 

option is not selectable.

g

   Press the PERM. PRESS key pad once to advance to next 

code.

COIN/DEBIT OPTION

Both coin & debit selected.
Coins selected, debit disabled.                                          

Press DELICATES key pad for this selection.
Debit Card selected, coins disabled.  

Press DELICATES key pad for this selection.
Enhanced Debit is self-selected when a Generation 2 

card reader is installed in the dryer. The “Ed” option 

cannot be manually selected or deselected.

g

   Press the PERM. PRESS key pad once to advance to next 

code.

PRICE SUPPRESSION OPTION

This option is either SELECTED “ON” 

OR NOT SELECTED “OFF.” This option causes the 

customer display to show “AVAILABLE” or “ADD” 

rather than the amount of money to add. (Used mainly 

in debit installations.)
Not Selected “OFF.”
Selected “ON.” Press the DELICATES key pad once for 

this selection.

g

   Press the PERM. PRESS key pad once to advance to next 

code.

CLEAR ESCROW OPTION

This option is either SELECTED “ON” 

OR NOT SELECTED “OFF.” When selected, money 

held in escrow for 30 minutes without further escrow  

or cycle activity will be cleared.
Selected “ON.”
Not sele cted “OFF.” Press the DELICATES key pad 

once for this selection.

g

   Press the PERM. PRESS key pad once to advance to next 

code.

PENNY INCREMENT OFFSET

This represents the penny increment price offset 

used in Generation 2 (Enhanced Debit) PR 

models. Choose from 0–4 pennies by pressing the 

WHITES AND COLORS key pad.

g

   Press the PERM. PRESS key pad once to advance to next 

code.

8. 0 0 

E. 0 0 

E. 0 0  

E.A C  

8. 0 0 

8.

C S 

J.C 8 

L. 0 0 

L. 0 0  

L.P S  

J.C 8 

J.C 8 

J.C 8 

J.E 8 

8.

C E 

8.

C E

 

8.0 0 

0. 0 0  
0. 0 0  

Summary of Contents for MLE24PDAYW

Page 1: ...doors with windows depending on model INSTRUCTIONS POUR L INSTALLATION D UNE S CHEUSE COMMERCIALE SUPERPOS E gaz 120 Volts 60 Hz ou lectrique 120 240 Volts 60 Hz Selon le mod le le pr sent appareil n...

Page 2: ...P 16 WARRANTY 21 DRYER SAFETY TABLE DES MATI RES S CURIT DE LA S CHEUSE 22 EXIGENCES D INSTALLATION 25 Outillage et pi ces 25 Exigences d emplacement 25 Sp cifications lectriques s cheuse gaz 26 Sp ci...

Page 3: ...and service must be performed by a qualified installer service agency or the gas supplier Clear the room building or area of all occupants WARNING Gas leaks cannot always be detected by smell Gas supp...

Page 4: ...connector when used must not exceed 3 feet FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance n It is recommended that th...

Page 5: ...00 mm or 10 250 mm pipe wrench n 8 200 mm or 10 250 mm adjustable wrench n Flat blade screwdriver n Phillips screwdriver n Adjustable wrench that opens to 1 25 mm or 1 25 mm hex head socket wrench n S...

Page 6: ...lt in death fire or electrical shock WARNING GROUNDING INSTRUCTIONS SAVE THESE INSTRUCTIONS For a grounded cord connected dryer This dryer must be grounded In the event of a malfunction or breakdown g...

Page 7: ...d metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the dryer WARNING Improper conn...

Page 8: ...ryer Rigid pipe connection The rigid pipe connection requires a combination of pipe fittings to obtain an in line connection to the dryer n Must include a shut off valve The supply line must be equipp...

Page 9: ...ss flexible metal vent to avoid sagging and kinking that will result in reduced airflow and poor performance The total length of flexible metal vent should not exceed 73 4 ft 2 4 m An exhaust hood sho...

Page 10: ...ty between the upper dryer and the collar insert the cotter pin through the connecting bolt 4 Close the control panel 5 Plug into a grounding 3 prong outlet 6 Check dryer operation Select a full heat...

Page 11: ...into slot of the dryer rear panel Secure cover with hold down screw Four wire power supply cord must have four No 10 copper wires and match a four wire receptacle of NEMA Type 14 30R The fourth wire g...

Page 12: ...outer terminal block screws Tighten screws 8 Tighten strain relief screws 9 Insert tab of the terminal block cover into slot of the dryer rear panel Secure cover with hold down screw D A C B 5 Remove...

Page 13: ...remaining wires Strip insulation back 1 25 mm Shape ends of wires into a hook C B A E D F 5 Remove the center terminal block screw 6 Remove the appliance neutral ground wire from the external ground...

Page 14: ...b of the terminal block cover into slot of the dryer rear panel Secure cover with hold down screw 5 Remove the center terminal block screw 6 Remove the appliance neutral ground wire from the external...

Page 15: ...er and allow it to complete a full heat cycle to make sure it is working properly You can change your door swing from a right side opening to a left side opening if desired 1 Open dryer door Remove bo...

Page 16: ...ear to work well after repair is finished but failure may occur at a later date due to ESD stress n Use an anti static wrist strap Connect wrist strap to green ground connection point or unpainted met...

Page 17: ...the equivalent of one coin coin 1 CONTROL SET UP PROCEDURES IMPORTANT Read all instructions before operating The fabric setting key pads along with the digital display are used to set up the dryer con...

Page 18: ...Y COUNTER OPTION This option is either SELECTED ON or NOT SELECTED OFF Not Selected OFF Selected ON Press the DELICATES key pad 3 consecutive times to select ON and 3 consecutive times to remove Not S...

Page 19: ...SC 6 05 6 05 C 20 C 20 CODE EXPLANATION COIN SLIDE OPTION This option is either SELECTED ON or NOT SELECTED OFF Not Selected OFF Selected ON Press the DELICATES key pad 3 consecutive times for this se...

Page 20: ...is sensing voltage with the door open or when the motor shouldn t be on The control does not know if the relay is bad stuck on the relay drive circuit is bad shorted causing the motor relay to stay o...

Page 21: ...epairs to parts or systems resulting from unauthorized modifications made to the commercial appliance 7 The removal and reinstallation of your commercial appliance if it is installed in an inaccessibl...

Page 22: ...e non respect des instructions Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez vous d...

Page 23: ...SSEMENT Pour votre s curit les renseignements dans ce manuel doivent tre observ s pour r duire au minimum les risques d incendie ou d explosion ou pour viter des dommages au produit des blessures ou u...

Page 24: ...une recommandation sp cifique dans le guide d utlilisation et d entretien ou publi e dans les instructions de r paration par l utilisateur que vous comprenez et pouvez ex cuter avec comp tence CONSERV...

Page 25: ...ur Outillage et pi ces Rassembler les outils et pi ces n cessaires avant de commencer l installation Lire et respecter les instructions d installation fournies avec chacun des outils de cette liste Ou...

Page 26: ...tterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 n L appareil doit tre aliment par un circuit lectrique de 120 V CA seulement 60 Hz prot g par...

Page 27: ...un circuit ind pendant monophas quatre conducteurs ou trois conducteurs 120 240 V 60 Hz CA seulement ou un circuit 120 208 V trois ou quatre conducteurs si ceci est sp cifi sur la plaque signal tique...

Page 28: ...uyau rigide La connexion du tuyau rigide n cessite une combinaison de raccords pour obtenir une connexion de la s cheuse en ligne n Robinet d arr t n cessaire Conform ment aux prescriptions du Nationa...

Page 29: ...tions permettra de r pondre convenablement ce crit re n Le conduit d vacuation de la s cheuse ne doit pas tre raccord une vacuation de gaz une chemin e un mur un plafond un grenier un vide sanitaire o...

Page 30: ...ype bo te et persiennes Clapet inclin Type bo te persiennes Inclin de 21 2 po 64 mm n Un ensemble antirefoulement est n cessaire et est fourni par un distributeur de buanderie commercial et devrait tr...

Page 31: ...d sir Ne pas craser ni deformer le conduit d vacuation V rifier que la s cheuse est de niveau 3 V rifier que la canalisation souple de gaz n est pas d form e Achever l installation 1 Une fois la s che...

Page 32: ...terre est raccord de mani re permanente au conducteur neutre fil blanc dans la s cheuse Si la s cheuse doit tre raccord e un c ble d alimentation quatre fils le conducteur neutre de liaison la terre d...

Page 33: ...te du panneau arri re de la s cheuse Immobiliser le couvercle avec la vis de retenue Le cordon d alimentation quatre conducteurs doit comporter quatre conducteurs de cuivre N 10 et on doit disposer d...

Page 34: ...s du serre c ble 9 Ins rer l onglet du couvercle du bloc de connexion dans la fente du panneau arri re de la s cheuse Immobiliser le couvercle avec la vis de retenue 5 ter la vis de la borne centrale...

Page 35: ...ns d installation qui suivent selon le type de raccordement Quatre conducteurs m thode recommand e Trois conducteurs si un circuit quatre conducteurs n est pas disponible M thode de c blage direct U s...

Page 36: ...ucteur de liaison la terre de l appareil de la vis de connexion du conducteur externe de liaison la terre Connecter le conducteur de liaison la terre et le conducteur neutre conducteur blanc ou centra...

Page 37: ...e la s cheuse en marche la laisser ex cuter un programme complet avec chaleur pas le programme de s chage l air pour v rifier qu elle fonctionne correctement Le sens d ouverture de la porte peut tre c...

Page 38: ...ce m tallique non peinte de l appareil OU Toucher plusieurs fois du doigt la vis verte de liaison la terre ou une surface m tallique non peinte de l appareil n Avant de retirer la pi ce de son sachet...

Page 39: ...omatiquement lors de l ouverture de la porte Pr t pour carte de d bit Cet appareil est pr configur pour l utilisation des cartes de d bit il est compatible avec une vari t de syst mes de paiement par...

Page 40: ...usine pour 5 minutes par pi ce Exemple 6 pi ces de 0 25 x 5 minutes 30 minutes La touche WHITES AND COLORS permet de faire varier la valeur dans la plage 1 99 minutes g Appuyer une fois sur la touche...

Page 41: ...6 3 0 6 8 00 8 00 CODE EXPLICATION JOUR POUR PRIX SP CIAL Ceci repr sente le jour de la semaine s lectionn et la s lection de la tarification sp ciale pource jour Un chiffre suivi de 0 indique que ce...

Page 42: ...ois cons cutives sur la touche DELICATES pour cette s lection Lorsqu on s lectionne le mode de glissi re pi ces s lectionner une valeur b gale la valeur despi ces plac es dans la glissi re en multiple...

Page 43: ...oll si le circuit d alimentation du relais est d faillant en court circuit provoquant le blocage du relais du moteur en position active ou si le circuit de r troaction du relais est endommag Basse ten...

Page 44: ...toris e faite l appareil commercial 7 La d pose et la r installation de votre appareil commercial si celui ci est install dans un endroit inaccessible ou n est pas install conform ment aux instruction...

Reviews: