![Maytag MLE24PDAYW Installation Instructions Manual Download Page 12](http://html1.mh-extra.com/html/maytag/mle24pdayw/mle24pdayw_installation-instructions-manual_1748315012.webp)
12
12
A. Spade terminals with upturned ends
B. Ring terminals
C. Neutral (white or center)
D. 3/4" (19 mm) UL-listed strain relief
E. Neutral
A. External ground conductor screw
B. Center terminal block screw
C. Outer terminal block screws
D. Strain relief screw
E. Neutral (center wire)
F. Appliance neutral ground wire
A. Separate copper ground wire
B. External ground conductor screw
C. Appliance neutral ground wire
D. Center terminal block screw
E. Outer terminal block screws
F. Strain relief screw
G. Neutral (center wire)
G
F
E
Power Supply Cord,
Three-wire electrical connection
:
B
A
E
F
D
C
Three-wire power supply cord must
have three, No. 10 copper wires and
match a three-wire receptacle of
NEMA Type 10-30R.
E
C
D
This blade connected to
this conductor.
B
A
5.
Loosen or remove the center terminal
block screw.
6.
Connect the neutral wire (white or center)
of the power supply cord to the center
terminal screw of the terminal block.
Tighten screw.
7.
Connect the other wires to outer terminal
block screws. Tighten screws.
8.
Tighten strain relief screws.
9.
Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover
with hold-down screw.
D
A
C
B
5.
Remove the center terminal block screw.
6.
Remove the appliance neutral ground
wire from the external ground conductor
screw. Connect the appliance neutral
ground wire and the neutral wire (white or
center) of the power supply cord under
the center terminal block screw. Tighten
screw.
7.
Connect the other wires to outer terminal
block screws. Tighten screws.
8.
Tighten strain relief screws.
9.
Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover
with hold-down screw.
10.
After reattaching the terminal cover,
connect a separate copper ground wire
from the external ground conductor screw
to an adequate ground.
If codes permit and a separate ground wire
is used, it is recommended that a qualified
electrician determine that the ground path
is adequate.
Use this method where local codes permit
connecting neutral ground wire to neutral wire:
Use this method where local codes do not permit
connecting neutral ground wire to neutral wire: