background image

3

Location Requirements 

You will need

A location that allows for proper exhaust installation. A gas 
dryer must be exhausted to the outdoors. See “Venting 
Requirements.”

A grounded electrical outlet located within 2 ft (61 cm) of 
either side of the dryer. See “Electrical Requirements.”

A sturdy floor to support the dryer and a total weight (dryer 
and load) of 200 lbs (90.7 kg). The combined weight of a 
companion appliance should also be considered.

A level floor with a maximum slope of 1" (2.5 cm) under entire 
dryer. (If slope is greater than 1" [2.5 cm], install Extended 
Dryer Feet kit, Part No. 279810.) Clothes may not tumble 
properly and models with automatic sensor cycles may not 
operate correctly if dryer is not level.

Do not operate your dryer at temperatures below 45ºF (7ºC). At 
lower temperatures, the dryer might not shut off at the end of an 
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will be 
exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, 
installation of the dryer in garages, closets, mobile homes or 
sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the 
same closet as a dryer.

Installation Clearances

The location must be large enough to allow the dryer door to 
open fully. 

Dryer Dimensions

*Most installations require a minimum 5" (12.7 cm) clearance 

behind the dryer for the exhaust vent with elbow. See “Venting 
Requirements.”

Installation spacing for recessed area or closet installation

The following spacing dimensions are recommended for this 
dryer. This dryer has been tested for spacing of 0" (0 cm) 
clearance on the sides and rear. Recommended spacing should 
be considered for the following reasons:

Additional spacing should be considered for ease of 
installation and servicing.

Additional clearances might be required for wall, door and 
floor moldings.

Additional spacing should be considered on all sides of the 
dryer to reduce noise transfer.

For closet installation, with a door, minimum ventilation 
openings in the top and bottom of the door are required. 
Louvered doors with equivalent ventilation openings are 
acceptable.

Companion appliance spacing should also be considered.  

*Required spacing

WARNING

Explosion Hazard

Keep flammable materials and vapors, such as 
gasoline, away from dryer.

Place dryer at least 18 inches (46 cm) above the floor 
for a garage installation.

Failure to do so can result in death, explosion, or fire.

A. Small Opening Side-Swing Door
B. Large Opening Side-Swing Door

C. Wide Opening Side-Swing Door
D. Wide Opening Hamper Door

A. Recessed area
B. Side view - closet or confined area

C. Closet door with vents

 

   

 

   

   

 

   

43

³⁄₈

"

(110 cm)

*26"

(66 cm)

29"

(73.66 cm)

A

15¼"

(38.74 cm) 43

³⁄₈

"

(110 cm)

*27¾"

(70.5cm)

29"

(73.66 cm)

B

22 ¾"

(57.8 cm)

43

³⁄₈

"

(110 cm)

13 ¾"

(34.9 cm)

*27 ¾"

(70.5 cm)

29"

(73.66 cm)

D

43

³⁄₈

"

(110 cm)

*27 ¾"

(70.5 cm)

29"

(73.66 cm)

C

22 ¾"

(57.8 cm)

A

B

C

    18"*
(45.7 cm)

  1"
(2.5 cm)

       29"
(73.66 cm)

        1"
   (2.5 cm)

        1"*
    (2.5 cm)

14" max.*
(35.6

 

cm)

   27¾"
(70.5 cm)

   5"*
 (12.7 cm)

  48 in.  
(310 cm  )

2

*

2

  24 in.
(155 cm  )

*

2

       3"*
(7.6 cm)

       3"*
(7.6 cm)

Summary of Contents for MGDC400VW - Centennial 29" Gas Dryer

Page 1: ...Planification du syst me d vacuation 16 Installation du syst me d vacuation 17 Installation des pieds de nivellement 17 Raccordement au gaz 18 Raccordement du conduit d vacuation 18 Mise niveau de la...

Page 2: ...lding Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be...

Page 3: ...12 7 cm clearance behind the dryer for the exhaust vent with elbow See Venting Requirements Installation spacing for recessed area or closet installation The following spacing dimensions are recommend...

Page 4: ...on IPS pipe is recommended approved aluminum or copper tubing is acceptable for lengths under 20 ft 6 1 m if local codes and gas supplier permit If you are using Natural gas do not use copper tubing L...

Page 5: ...Observe all governing codes and ordinances The dryer exhaust must not be connected into any gas vent chimney wall ceiling or a concealed space of a building If using an existing vent system Clean lin...

Page 6: ...ch PlanVentSystem Choose your exhaust installation type Recommended exhaust installations Typical installations vent the dryer from the rear of the dryer Other installations are possible Standard exha...

Page 7: ...ng times and increased energy usage The Vent system chart provides venting requirements that will help to achieve the best drying performance Vent system chart NOTE Side and bottom exhaust installatio...

Page 8: ...st be used to connect the dryer to the existing gas line Shown is a recommended connection Your connection may be different according to the supply line type size and location 3 Open the shutoff valve...

Page 9: ...screws in cabinet are in large part of hinge slot Pull door forward off screws Set door handle side up on top of dryer Remove top screws from cabinet 4 Remove screws attaching hinges to door 5 Remove...

Page 10: ...Temperature setting If the dryer will not start check the following Dryer is plugged into a grounded 3 prong outlet Electrical supply is connected Household fuse is intact and tight or circuit breake...

Page 11: ...ront le symbole d alerte de s curit et le mot DANGER ou AVERTISSEMENT Ces mots signifient IMPORTANTES INSTRUCTIONS DE S CURIT CONSERVEZ CES INSTRUCTIONS Avant de jeter ou de ranger votre vieille s che...

Page 12: ...la s cheuse n est pas d aplomb le linge peut ne pas culbuter convenablement et les programmes command s par des d tecteurs automatiques peuvent ne pas fonctionner correctement Ne pas faire fonctionne...

Page 13: ...riqu es Titre 24 HUD partie 280 ou de la Norme canadienne des habitations pr fabriqu es CAN CSA Z240MH L installation dans une maison mobile exige Un syst me d vacuation en m tal disponible l achat ch...

Page 14: ...t manuel individuel soit install en de de 6 pieds 1 8 m de la s cheuse et l emplacement doit tre facile atteindre pour l ouverture et la fermeture Exigences concernant le raccordement au gaz Utiliser...

Page 15: ...vacuation pour atteindre le meilleur rendement de s chage En cas de nouveau syst me d vacuation Mat riel pour l vacuation Utiliser un conduit d vacuation en m tal lourd Ne pas utiliser un conduit de...

Page 16: ...ypiques consistent acheminer le conduit d vacuation l arri re de la s cheuse D autres installations sont possibles Installations standard du conduit d vacuation l aide d un conduit m tallique rigide o...

Page 17: ...des syst mes d vacuation fournit les exigences d vacuation qui vous aideront atteindre la meilleure performance de s chage Tableau des syst mes d vacuation REMARQUE Les installations d vacuation du c...

Page 18: ...z existante On voit ci dessous une illustration d un raccordement recommand Le raccordement peut varier selon le type d alimentation la dimension et l emplacement 3 Ouvrir le robinet d arr t du condui...

Page 19: ...che de la porte vers la gauche ou la droite dans son logement pour ajuster l alignement Porte r versible extra large pivotement lat ral 1 Placer une serviette A sur la s cheuse pour prot ger la surfa...

Page 20: ...t sur la s cheuse 7 Jeter recycler tout le mat riel d emballage 8 Lire Utilisation de la s cheuse dans les Instructions pour l utilisateur de la s cheuse 9 Essuyer soigneusement l int rieur du tambour...

Reviews: