113307 - 7

Maytag Co.

17

3. Piping Connections

ALL

 components/materials 

must conform

 to National Fuel Gas Code Specifications ANSI Z223.1-LATEST

EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid
Propane [L.P.] Gas) or LATEST EDITION (for General Installation and Gas Plumbing), as well as local
codes and ordinances and 

must be 

done by a qualified professional.  It is important that gas pressure

regulators meet applicable pressure requirements, and that gas meters be rated for the total amount of

ALL

 the appliance Btu being supplied.

The dryer is provided with a 1/2” N.P.T. inlet pipe connection extending out the back area of the burner
box.  The minimum pipe size (supply line) to the dryer is 1/2” diameter.  For ease in servicing, the gas supply
line of each dryer must have its own shutoff valve.

The size of the main gas supply line (header) will vary depending on the distance this line travels from the
gas meter or, in the case of L.P. gas, the supply tank, other gas-operated appliances on the same line, etc.
Specific information regarding supply line size 

should be

 determined by the gas supplier.

NOTE:

Undersized gas supply piping can create a low or inconsistent pressure, which will result in
erratic operation of the burner ignition system.

Consistent gas pressure is essential at 

ALL

 gas connections.  It  is  recommended that a 3/4-inch

(19.05 mm) pipe gas loop be installed in the supply line servicing a bank of dryers.  An in-line pressure
regulator 

must be

 installed in the gas supply line (header) if the (natural) gas pressure exceeds 12.0 inches

(29.9 mb) of water column (W.C.) pressure.  (Refer to the 

illustrations 

below.)

Summary of Contents for MDG30MNV

Page 1: ...voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incendies L installation et l entretien doivent tre assur s par un installateur o...

Page 2: ...nflammables proximit decet appareil ou de tout autre appareil We have tried to make this manual as complete as possible and hope you will find it useful The manufacturer reserves the right to make cha...

Page 3: ...IFNEARDRYERSINOPERATION CAUTION DRYERSSHOULDNEVERBELEFTUNATTENDEDWHILEINOPERATION FORYOUR SAFETY DONOTDRYMOPHEADSINTHEDRYER DONOTUSEDRYERINTHEPRESENCEOFDRYCLEANINGFUMES WARNING UNDER NO CIRCUMSTANCES...

Page 4: ...cluded with the dryer WARNING DRYER MUST NEVER BE OPERATEDWITHOUTTHE LINTFILTER SCREEN IN PLACE EVENIFANEXTERNALLINTCOLLECTIONSYSTEMISUSED Dryer must not be installed or stored in an area where it wil...

Page 5: ...ration for Operation Start Up 18 I Preoperational Tests 19 J Preoperational Instructions 20 K Shutdown Instructions 21 SECTIONIV SERVICE PARTSINFORMATION 22 A Service 22 B Parts 22 SECTIONV WARRANTYIN...

Page 6: ...building or area of ALL occupants e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions f If you cannot reach your gas supplier call the fire department 4...

Page 7: ...perlywillVOIDTHEWARRANTY 9 UNDER NO CIRCUMSTANCES should the dryer door switch lint door drawer switch or heat safety circuit ever be disabled WARNING PERSONALINJURYOR FIRE COULD RESULT SHOULD THE DRY...

Page 8: ...S A F E WATER CONNECTION 3 4 11 5 NH VOLTAGE AVAILABLE 120v 1 2w 60 Hz APPROX WEIGHT UNCRATED 534 lbs 242 kg APPROX WEIGHT CRATED 571 lbs 259 kg HEAT INPUT 100 000 Btu hr 25 200 kcal hr AIRFLOW 460 c...

Page 9: ...113307 7 Maytag Co 5 NOTE Themanufacturerreservestherighttomakechangesinspecificationsatanytimewithout noticeorobligation Specifications...

Page 10: ...t chamber To remove the two 2 bolts located in the lint chamber area remove the lint door drawer With the skid removed to make it easier to slide the dryer into its final position slightly lower ALL f...

Page 11: ...st ductwill be necessary 9 The dryer must be installed with adequate clearance for air openings into the combustion chamber CAUTION This dryer produces combustible lint and must be exhausted to the ou...

Page 12: ...he area must be increased It is not necessary to have separate make up air openings for each dryer Common make up air openings are acceptable However they must be set up in such a manner that the make...

Page 13: ...nspection doors should be installed at strategic points in the exhaust ductwork for periodic inspection and cleaning IMPORTANT When connecting ductwork to the dryer exhaust duct be sure that when scre...

Page 14: ...n A 30 feet 9 144 meters The minimum diameter of this ductwork must be at least Dimension B 8 inches 20 32 cm Including basket tumbler dryer elbow connections or elbows used for outside protection fro...

Page 15: ...ctwork Dimension A must be at least 8 inches 20 32 cm IMPORTANT No more than four 4 dryers should be connected to one 1 main common duct The illustration below shows the minimum cross sectional area f...

Page 16: ...must be connected with copper wire only DO NOT use aluminum wire it could create a fire hazard The copper conductor wire cable must be of proper ampacity and insulation in accordance with electric co...

Page 17: ...SA C22 1 1990 or LATEST EDITION The ground connection may be to a proven earth ground at the location service panel For added personal safety when possible it is suggested that a separate ground wire...

Page 18: ...1 gas dryers are made into the rear service box located at the upper left area of the dryer Single Phase Electrical Lead Connections Black Positive White or Red Neutral or L2 Green Ground A ground lug...

Page 19: ...use irreparable damage to the gas valve which willVOIDTHEWARRANTY WARNING FIRE OR EXPLOSION COULD RESULT DUE TO FAILURE OF ISOLATINGOR DISCONNECTINGTHE GAS SUPPLYAS NOTED 1 Gas Supply The gas dryer in...

Page 20: ...hr 25 200 kcal hr 1 Natural Gas Regulation is controlled by the dryer s gas valve s internal regulator Incoming supply pressure must be consistent between a minimum of 6 0 inches 14 92 mb and a maximu...

Page 21: ...er is 1 2 diameter For ease in servicing the gas supply line of each dryer must have its own shutoff valve The size of the main gas supply line header will vary depending on the distance this line tra...

Page 22: ...or less than 1 2 psig 3 5 kPa H PREPARATION FOR OPERATION START UP The following items should be checked before attempting to operate the dryer 1 Read ALL CAUTION WARNING and DIRECTION labels attache...

Page 23: ...ion attempts If there is no flame after the third ignitionattemptthemodulewilllockoutuntilitismanuallyreset Toresettheignitionsystem open and close the main door and restart the dryer b A gas pressure...

Page 24: ...he L E D display will read MANUAL DRYING CYCLE D 00 00 MIN REMAIN NOTE The dryer can be stopped at any time by pressing the STOP CLEAR key at this time the dryer will go into a cycle pause If the STOP...

Page 25: ...ryer is to be shutdown taken out of service for a period of time the following must be performed 1 Discontinue power to the dryer either at the external disconnect switch or the circuit breaker 2 Disc...

Page 26: ...hen contacting the Maytag Co be sure to give the correct model number and serial number so that the inquiry is handled in an expeditious manner B PARTS Replacement parts should be purchased from the d...

Page 27: ...must be completed and returned for each individual dryer NOTE Besuretoincludetheinstallationdatewhenreturningthewarrantycard s B WARRANTY For a copy of the manufacturer s commercial warranty covering...

Page 28: ...AND OTHER FLAMMABLE VAPORSAND LIQUIDS NOTE Suggested time intervals shown are for average usage which is considered six 6 to eight 8 operational running hoursperday IMPORTANT Dryer produces combustib...

Page 29: ...nnections and nonpermanent gas connections unions shutoff valves and orifices Motor and drive belts should be examined Cracked or seriously frayed belts should be replaced Tighten loose V belts when n...

Page 30: ...e manufacturer to gather information on your particular dryer 3 MANUFACTURINGCODE NUMBER The number issued by the manufacturer which describes ALL possible options on your particular model 4 TYPE OFHE...

Page 31: ...ompleting installation of the replacement microprocessor controller computer board reestablish power to the dryer b Start the drying cycle by pressing any of the preset cycles in letters A F c Verify...

Page 32: ...s normal operation No L E D indicator indicates a power or an internal failure has occurred 3 For Models with DSI Module Type II Theory of Operation Start the drying cycle When the gas burner ignites...

Page 33: ...attended to the Phase 7 microprocessor controller computer will display that the system was activated BEFORE YOU START CHECK LOCAL CODES AND PERMITS Call your local water company or the proper munici...

Page 34: ...ession system will be INOPERATIVE IMPORTANT Appliance is to be connected to the water mains using a new hose set and the old hose set should not be reused 2 Water Connections The water connection is m...

Page 35: ...e T or three way fitting located in the outlet supply side of the water solenoid valve The use and connections of this manual bypass are at the option or discretion of the owner The water connection f...

Page 36: ...Part No 113307 7 06 26 08 0...

Reviews: