©2006 Maytag Services
16026186
33
To avoid risk of electrical shock, personal injury or death;
disconnect power to unit before servicing.
Disassembly Procedures
WARNING
!
Drain Pump Removal
1. Disconnect power supply to unit.
2. Remove Back Cover.
3. Remove clamp and Drain Hose.
NOTE: There may be water remaining in the hose from
the last cycle.
4. Remove clamp and Pump Hose.
5. Remove wiring connector.
6. Remove three 13mm bolts securing Drain Pump to
base.
7. Remove screw securing Drain Pump to bracket. Twist
Drain Pump clockwise to remove.