August 2006 3
16027402
©2006 Maytag Services
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to washer before servicing, unless
testing requires power.
SERIES 45 - current
Machine Control Board INPUT/OUTPUT
Description
Connector/
Pin Number
Reference
To
Connector/
Pin Number
Voltage
Comments
Bleach water valve output
P1(4)
P6(2)
120 VAC
Cold water valve output
P1(3)
P6(2)
120 VAC
500-1K ohms
Door Lock output
P1(1)
P6(2)
120 VAC
60 millisecond pulse
Door lock switch input
P4(5)
P4(4)
12 VDC
Door switch input
P8(4)
P6(2)
120 VAC
Door unlock output
P8(3)
P6(2)
120 VAC
60 millisecond pulse
Drain pump output
P8(1)
P6(2)
120 VAC
High water level - input
P1(6)
P6(2)
120 VAC
Hot water valve output
P1(2)
P6(2)
120 VAC
500 - 2K ohms
L1- machine control board
P6(1)
P6(2)
120 VAC
L1- motor control
P8(2)
P6(2)
120 VAC
Lower water level - input
P4(8)
P4(4)
12 VDC
Motor control tach
P4(2)
P4(4)
12 VDC
Neutral (120 VAC)
P6(2)
Neutral
Unbalance input
P3(4)
P4(4)
12 VDC
Softener water valve
P1(5)
P6(2)
120 VAC
Torque PWM
P4(3)
P4(4)
12 VDC
Water valve thermistor
P4(6)
P4(7)
(10K-85K ohms)
Heater
P6(3)
P8(4)
120 VAC
Thermistor-Heater
P3(1)
P3(2)
120 VAC
500 - 40K ohms
Less than 10 ohms when closed
Less than 10 ohms when closed
Less than 10 ohms when closed
PWM signal between 0 & 100% duty cycle
500 - 2K ohms
Component Testing Procedures