6-3
Diagnostic: Moisture Sensor
Locate the two metal strips on the face of the
lint screen housing. Bridge these strips with a
wet cloth or a finger. If a beep is heard, and a
software revision number is displayed on the
console, the sensor is okay. If not, or if a beep
tone is heard before bridging the moisture
strips, go to TEST #4, (Moisture Sensor Test),
step 2, on page 6-10.
Diagnostic: Door Switch
Opening the door should cause a beep tone
and a number and letter to be indicated in the
2-digit display. Closing the door firmly should
cause a beep tone and the display to go blank,
or indicate “88”.
Diagnostic: Console switches and indica-
tors.
Pressing each button, or turning the cycle se-
lector to each cycle, should cause a beep tone
and control one or more LEDs. Pressing the
Hold To Start button will also control the motor
and heater, while the 2-digit display will indi-
cate a software project identification number.
Start button
controls these
LEDs
Control On button controls this LED
Each button controls
all LEDs above button
Cycle selector controls
LED where pointing
Turns off all LEDs and
exits diagnostic mode
This button controls
the left digit
This button controls
the right digit
Controls Status LEDs and turns on dryer