4-4
REMOVING THE CONSOLE & THE
TOUCHPAD SUBASSEMBLY
1.
Unplug dryer or disconnect power.
2.
Turn off gas supply to dryer.
3.
Pull the dryer away from the wall and
remove the top cover (see steps 4 and 5
on page 4-2 for the procedure).
4.
Remove the three screws from the elec-
tronic control board bracket, and tip the
bracket assembly inside the dryer (see
step 6 on page 4-2 for the procedure).
5.
Disconnect the ends of the two ribbon
cables from the electronic control board
connectors P3 and P4.
6.
Remove the two screws from the console
bracket.
P3
P4
Press In On Clips To
Release Cables
Electronic
Control
Board
Lift Console Bracket From
Flange On Both Sides
8.
Lift the console straight up until the brack-
ets are free of the left and right side panel
flanges and remove the console.
Viewed From Back Of Console
Side Panel Flange
7.
Open the door and pull out on the bottom
of the console to release the locking tabs
from the door panel.
Console Bracket Screws
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
Summary of Contents for Epic MED/GD9600S
Page 4: ... iv NOTES ...
Page 45: ...4 16 Squeeze Arms 8 Squeeze the locking arms and remove the socket from the drum light holder ...
Page 71: ...6 14 NOTES ...
Page 73: ...7 2 NOTES ...