Troubleshooting
48
E48
NO PUMP DOWN
The control is unable to enter the Pump
Down Mode because indoor heat has
been turned on by thermostat. Please set
thermostat to off position.
Heat provided by secondary heating source
Turn off heater using thermostat before operation
49
E49
NO CHARGE MODE
The control is unable to enter Charging
Mode because indoor heat has been
turned on by thermostat. Please set
thermostat to off position.
Heat provided by secondary heating source
Turn off heater using thermostat before operation
50
E50
LINE VOLT CTRL
This indicates there is a voltage issue on
the control board. See service manual for
troubleshooting information.
High or low voltage from supply
Faulty control board
Correct low/high line voltage condition; Contact local
utility if needed
Replace control board if necessary
51
E51
OD COMM ERROR
This indicates potential communication
issues have been detected by the
outdoor control board.
Communication wiring disconnected
Check communication wiring; Repair as needed
52
-
COMP FAIL MINOR
This error indicates the equipment is
experiencing frequent compressor faults.
Control has determined continued
operation is acceptable. This indicates
they may be a problem with the
equipment.
Stop valve not completely open
The compressor wire is lost phase
Compressor motor failure
Check the opening of stop valve, should be full open;
Repair/replace if needed
Check the wire between control board and compressor
Inspect compressor motor for proper function; Replace
if necessary
ClimateTalk
Fault Code
PCB LED
Display
Transmitted ClimateTalk
Message
s
n
o
it
c
A
e
v
it
c
e
r
r
o
C
s
e
s
u
a
C
e
l
b
a
b
o
r
P
tl
u
a
F
t
a
t
s
o
m
r
e
h
T
35
E35
HIGH CURRENT
Board detected a high current condition.
Short circuit condition
Stop valve not completely open
Overcharge
Faulty control board
Faulty compressor
Check installation clearances.
Check the opening of stop valve, should be full open;
Repair/replace if needed
Check refrigerant charge level; Adjust if needed
Replace control board if necessary
Check the compressor; Repair/replace if needed.
36
E36
STARTUP ERROR
The control encountered an abnormal
condition during the startup procedure.
Blocked/restricted condenser coil and/or
lines
The compressor wire is lost phase
Inconsistent compressor load
Faulty control board
Check and clean condenser coil and/or lines
Check the wire between control board and compressor
Replace control board if necessary
37
E37
OD CTRL FAIL4
Indicates the control board may need to
be replaced.
Outdoor fan motor not connected properly
Faulty control board
Check wiring from outdoor fan motor to control board;
Repair if needed
Replace control board if necessary
38
E38
COMP VOLTAGE
The control has detected a voltage related
issue with the compressor.
High or low voltage from supply
The compressor wire is lost phase
Faulty control board
Correct low/high line voltage condition; Contact local
utility if needed
Check the wire between control board and compressor
Replace control board if necessary
39
E39
OD CTRL FAIL5
Indicates the control board may need to
be replaced.
Thermistors inoperable or improperly
connected
Faulty control board
Check the connection to thermistors; Repair/replace if
needed
Replace control board if necessary
40
E40
COMP MISMATCH
Control determines that its compressor
requirement is different than the
compressor capability.
Bluetooth® Shared Data Loader
●
Control board mismatch
Check Bluetooth® Shared Data Loader BTSDL01 data
Verify control board size vs. air conditioner model;
Replace control board if necessary
41
E41
LOW REFRIGERANT
The control has detected a low refrigerant
condition.
Refrigerant leak
Low refrigerant charge
Thermisters inoperable or not properly
connected
Test for system leaks using leak test procedure
Check refrigerant charge level; Adjust if needed
Checkthe connection to thermistor; Repair/replace if
needed
42
E42
LOW LINE VOLT
Control detects a low power supply
voltage condition.
Low line voltage supply
Check circuit breakers and fuses; Replace if needed
Verify unit is connected to power supply as specified
on rating plate
Correct low line voltage condition; Contact local utility if
needed
43
E43
HIGH LINE VOLT
Control detects a high power supply
voltage condition.
High line voltage supply
Verify unit is connected to power supply as specified
on rating plate
Correct high line voltage condition; Contact local utility
if needed
44
E44
OP TEMP RANGE
The control detects the outdoor
temperature outside recommended
operational range. Unit may continue to
operate normally.
Ambient air conditions too high or low
Cycle power; re-try during usable ambient temperature
range
45
E45
NO COOLING TEST
The control is unable to start the Cooling
mode test because indoor heat has been
turned on by thermostat. Please set
thermostat to off position.
Heat provided by secondary heating source
Turn off heater using thermostat before running AHRI
mode
46
E46
NO HEATING TEST
The control is unable to sart the Heating
mode test becaue indoor heat has been
turned on by thermostat. Please set
thermostat to off position.
Heat provided by secondary heating source
Turn off heater using thermostat before running AHRI
mode
47
E47
NO SYS VER TEST
The control is unable to start the System
Verification test because indoor heat has
been turned on by thermostat. Please set
thermostat to off position.
Heat provided by secondary heating source
Turn off heater using thermostat before operation
BTSDL01 not correct.
vs. air conditioner model
(*1) This message is displayed when using the CTK04 thermostat
(*2) Network communication error (Refer to “NETWORK TROUBLESHOOTING”)
Summary of Contents for Amana VZC20
Page 6: ...6...
Page 48: ...48 4 Select YES to continue 5 Select HEAT PUMP 6 Select SYS SETUP...
Page 55: ...55 NOTE BOOST MODE is applicable only for AVZC200 AB and GVZC20 AA or later revision...
Page 56: ...56 https partnerlinkmarketing goodmanmfg com goodman info finder plus...
Page 57: ...57 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 58: ...58 THIS PAGE IS INTENTIONALLY LEFT BLANK...