HIGH VOLTAGE!

 DISCONNECT ALL POWER BEFORE SERVICING.

MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO

MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

WARNING

ASPT**14**

ARUF**14**

USE COPPER WIRE

SPEEDUP

COPPER POWER SUPPLY

(SEE RATING PLATE)

EQUIPMENT GROUND

BL

BL

SEE

NOTE 3

BK

M1

BR

BR

RC

EM

RD

BL

BK

RD

PU

WH

EBTDR

SR

BL

G

RD

XFMR-R

XFMR-C

C

R

RD

GR

SEE NOTES 2 & 6

BL RD GR WH BR

5

NO

COM

NC

K1

K1

PU

PU

RD

RD

C

BK

BR

PLF

BK

1

RD

PU

2

3

240

24V 4

1

2 3

TR

RD

SEE

NOTE 4

BL

BR

4

5

WH

6

7

8

9

PLM

GRD

1

BK

2

3

RD

L2

L1

4

5

6

7

8

9

0140A00242-A

PLM

PLF

TR

FACTORY WIRING

FIELD WIRING

NOTES:

TIME DELAY RELAY

STRAIN RELIEF

EVAPORATOR MOTOR

ELECTRONIC BLOWER

RUN CAPACITOR

SR

EM

EBTDR

RC

BK

RD

BL

YL

BLUE

BLACK

RED

YELLOW

COMPONENT CODE

BROWN

PURPLE

GREEN

PU

BR

GR

FEMALE PLUG CONNECTOR

MALE PLUG CONNECTOR

TRANSFORMER

   HIGH VOLTAGE

   LOW VOLTAGE

   HIGH VOLTAGE

   LOW VOLTAGE

PLF

3

2

COLOR CODE

RD

TR

WH

6

BR

5

PLF

4

4

24V

5

SEE NOTE 1

1

2

3

RC

HI

EM

GR

WIRING CODE

BL

EBTDR

LO

COM

NC

M1

EBTDR

NO

208/240

VOLTS

1

1 PLF

PLM

L1

PLM

2

L2

(M2)

PU

RC

(M1)

BK

BL

MEDIUM

3 SPEED

BR

HIGH

EM

(COM) RD

LOW

IF REPLACEMENT OF THE ORIGINAL WIRES

SUPPLIED WITH THIS ASSEMBLY IS NECESSARY

USE WIRE THAT CONFORMS TO THE

NATIONAL ELECTRIC CODE.

M2

PU

(TR 1)

M2

R

G

C

EBTDR

SEE NOTE 1

FL

FUSE LINK

TL

THERMAL LIMIT

SEE NOTE 5

R

RELAY

TERMINAL BLOCK SHOWN

FOR 50HZ MODELS ONLY

THREE SPEED MOTOR WIRING

(SELECT MODELS ONLY)

SEE NOTE 3

WHITE

WH

IELD WIRE

1) RED WIRES TO BE ON TRANSFORMER TERMINAL "3" FOR 240 VOLTS 

    AND ON TERMINAL "2" FOR 208 VOLTS.

2) SEE COMPOSITE WIRING DIAGRAMS IN INSTALLATION INSTRUCTIONS 

    FOR PROPER LOW VOLTAGE WIRING  CONNECTIONS.

3) CONFIRM SPEED TAP SELECTED IS APPROPRIATE FOR APPLICATION.

    IF SPEED TAP NEEDS TO BE CHANGED, CONNECT APPROPRIATE

    MOTOR WIRE (RED FOR LOW, BLUE FOR MEDIUM, AND BLACK FOR

    HIGH SPEED) ON "COM" CONNECTION OF THE EBTDR.

    INACTIVE MOTOR WIRES MUST BE CONNECTED TO "M1 OR M2" 

    ON EBTDR.

4) BROWN AND WHITE WIRES ARE USED WITH HEAT KITS ONLY.

5) EBTDR HAS A 7 SECOND ON DELAY WHEN "G" IS ENERGIZED

    AND A 65 SECOND OFF DELAY WHEN "G" IS DE-ENERGIZED.

6) LOW VOLTAGE FIELD WIRING TO BE N.E.C CLASS 2 WIRES.

COPPER POWER SUPPLY

(USE RATING PLATE)

USE MIN. 75° C FIELD WIRE

0140A00630-A

PLM

PLF

TR

FACTOR Y WIRING

FIELD WIRING

NOTES:

1. RED WIRES TO BE ON TRA NSFORMER TERMINAL "3" FOR 240 VOLTS AND ON

TERMINAL "2" FOR 208 V OLTS.

2. SEE COMPLETE WIRING DIAGRA MS IN INSTALLATION INSTRUCTIONS FOR

    PRO PER LOW VOLTA GE WIRING CONNEC TIONS.

3. "CON FIRM SPEED TAP SELECTION IS APPROPRIATE FOR APPLICATION . IF

SPEED TAP NEEDS TO BE CHAN GED, CONNECT PURPLE WIRE FROM TERMINAL7

    OF CR ( TERMINAL 4 OF ALTERN ATE)  R ELAY TO APPROPRIATE TAP AT TB”

4. BROWN AND WHITE WIRES ARE USED FOR HEAT KITS ON LY.

5. FUS E: 3A, 250V, 3AG ATO STYLE FUSE. OP TION AL FUSE 3 AM P CARTRID GE.

6. LO W VOLTA GE FIELD WIRING TO BE N.E.C CLASS 2 WIRES.

RELAY

EVAPORATOR M OTOR

TERMINAL BOARD

R

EM

TB

BK

RD

BL

YL

BLUE

BLACK

RED

YELLOW

COMPON ENT COD E

BROWN

PURPLE

GREEN

PU

BR

GR

FEMALE PLUG CONNECTOR
MALE PLUG CONNECTOR

TRANSFORMER

   HIGH VOLTAGE

LOW VOLTA GE

   HIGH VOLTA GE

LOW VOLTA GE

PLF

2

COLOR  CODE

TR

6

5

PLM

4

4

24V

5

1

2

3

EM

WIRING COD E

208/240 VOLTS

1

1 PLF

PLM

L1

PLM

2

L2

IF REPLACEMENT OF THE ORI GINAL WIRES

SUPPLIED WITH THIS A SSEMBLY IS NEC ESSARY,

USE WIRE THAT CONFOR MS TO THE NATION AL

ELECTRIC CO DE.

FL

FUSE LINK

TL

THERMAL LIMIT

CR

CONTRO L RELAY

WHITE

WH

L G N

W2

R

W1

C G

4

Y1

O

Y2

1

DH

3

25

A

B

1

C

EM

2

4

3

5

4

7

CR

1

SEE NOTE 1

USE COPPER WIRE

EQUIPMENT GROUND

BL

EM

YL

BL

5

BK

C

BK

PLF

BK

1

RD

2

3

240

24V

4

1

2

3

TR

RD

BL

BR

4

5

WH

6

7

8

9

PLM

GRD

1

2

3

4

5

6

7

8

9

A

B

1

7

4

CR

SEE NOTES 2 & 6

2

1

4

3

5

N

C

G

L

RD

PU

BL

BR
WH

BL

RD

GR

RD or BK

BL

RD

BK

RD

W2

R

W1

C G

4

Y1

O

Y2

1

DH

3

2

5

RD or BK

PU

BR

WH

OR

WH

WH

BL

GR

RD or BK

BL

L2

L1

SEE

NOTE 1

SEE

NOTE 4

1

3

5

4

2

ALTERNATE CONTR OL RELAY

BL

PU

RD

GR

WH

BL

1

3

2

4

CR

5

ALTERNATE HEAT RELAY

GRND

GROUND

SEE NOTES 2 & 6

FUSE

FUSE

TB

TB

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

Summary of Contents for Amana ARUF 14 Series

Page 1: ...ostats 14 12 6 Speed Tap Adjustment 14 13 Achieving 1 4 Low Leakage Rate 15 14 Start Up Procedure 15 15 Regular Maintenance 15 16 Airflow Data 16 17 Air Handler Low Voltage Connections 18 18 Wiring Di...

Page 2: ...or air handler is opera ng in any mode B10259 216 CO can cause serious illness including permanent brain damage or death Los equipos aparatos que producen mon xido tal como autom vil calentador de gas...

Page 3: ...consult the white business pages the yellow page section of the local tele phone book or contact HOMEOWNER SUPPORT GOODMAN MANUFACTURING COMPANY L P 19001 KERMIER ROAD WALLER TEXAS 77484 855 770 5678...

Page 4: ...scription Drain Port Plug DRAIN PORT PLUG KIT Table 1 Drip Pan Extension Side Drain Pan Screw B b A Main Drain Pan Drip Shield Bracket Drip Shield Pn a SIDE DRAIN PAN REMOVAL Figure 1 6 1 Upflow Insta...

Page 5: ...TO PULL THE COIL ASSEMBLY OUT FAIL URE TO DO SO MAY RESULT IN BRAZE JOINT DAMAGE AND LEAKS 3 Removal of the center support is required on units with 21 wide cabinet Remove and retain the two 2 screws...

Page 6: ...se clean gloves when handling coil assemblies 7 3 Special Instructions Units without a factory installed TXV come equipped with a flowrator piston for refrigerant expansion For most in stallations wit...

Page 7: ...alls Failure to do so will result in improper condensate drainage COIL INSTALLATION FOR DOWNFLOW Figure 8 Coil slides on the down ow bracket Upper Tie Plate Control Deck Down ow Bracket Center Support...

Page 8: ...tes possible leak 3 Replace the refrigerant tubing panel 4 Remove the spin closure on both the liquid and suction tubes using a tubing cutter 5 Insert liquid line set into liquid tube expansion and sl...

Page 9: ...finger tight SUBCOOL FORMULA SAT LIQUID LINE TEMP LIQUID LINE TEMP SUPERHEAT FORMULA SUCT LINE TEMP SAT SUCT TEMP NOTE Expansion valve system in ASPT models are already tuned for 16 SEER single stage...

Page 10: ...in high static pressure applications may require a deeper field constructed P style trap than is shown in Figure 12 to allow proper drainage and prevent condensate overflow Air Handler 3 MIN POSITIVE...

Page 11: ...indicated above the following formula is to be used TR kW x 3412 x Voltage Correction 1 08XCFM Where TR Temperature Rise kW Heater Kit Actual kW 3412 Btu per kW VC 96 230 Supply Volts 92 220 Supply V...

Page 12: ...pply to the unit The supply voltage must be measured and be in agreement with the unit nameplate power requirements and within the range shown 12 2 Wire Sizing Wire size is important to the operation...

Page 13: ...HEATER KITS Table 8 MINIMUM HEATER KIT AIRFLOW Table 9 3 5 6 8 10 15 19 20 25 ASPT25B14 715 715 715 715 850 ASPT29B14 715 715 715 715 875 1050 ASPT35B14 715 715 715 715 875 1050 ASPT37B14 715 715 715...

Page 14: ...aker Heat Kit The air handler has soft plastic cover on the upper ac cess panel and can be removed to allow the heater kit circuit breaker to be installed The circuit breakers have lugs for power supp...

Page 15: ...NG HIGH VOLTAGE DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT MULTIPLE POWER SOURCES MAY BE PRESENT FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE PERSON AL INJURY OR DEATH Prior to start...

Page 16: ...0 1210 1105 HIGH 1785 1735 1680 1625 1555 1440 1330 LOW 1410 1360 1290 1210 1120 1010 920 MED 1610 1540 1470 1390 1300 1190 1060 HIGH 1900 1830 1740 1645 1540 1420 1280 LOW 1420 1370 1310 1240 1125 10...

Page 17: ...5 5 8 5 0 9 5 5 9 0 0 0 1 0 5 0 1 0 1 1 1 3 T 0 1 0 1 5 5 0 1 5 9 0 1 5 3 1 1 0 8 1 1 0 2 2 1 0 6 2 1 0 1 3 1 0 6 3 1 4 T 0 6 2 1 5 9 2 1 0 3 3 1 0 7 3 1 5 9 3 1 5 3 4 1 5 7 4 1 5 1 5 1 0 6 5 1 5 T 0...

Page 18: ...the connections between room ther mostat and the air handlers and the connections between the air handlers and the Condensing Unit or Heat Pump with optional connections to Outdoor Thermostats For ea...

Page 19: ...CONDENSING UNIT 24V CONNECTIONS 18 GA 2 WIRES BLUE WHITE GREEN RED CONTACTOR COIL ARUF UNIT Low Voltage Wiring Diagram for Cooling Unit with optional heat kit 10KW and below W2 GREEN RED WHITE BLUE B...

Page 20: ...FALL RED GREEN WHITE BLUE AR UNIT R Y O W BL 18 GA 5 WIRE 18 GA 7 WIRE NOTE R G BR W BL R R I B 18 GA 6 WIRE NEEDED WHEN OT IS USED R 18 GA 7 WIRE NEEDED WHEN TWO OT S ARE USED 18 GA 5 WIRE BL O W Y...

Page 21: ...OR CODES RD RED YL YELLOW BL BLUE BR BROWN OR ORANGE WH WHITE COOLING UNIT WITH OPTIONAL HEAT KITS OF 10 kW AND BELOW G R C W1 Y W W2 Y2 Y1 O G R TB YL BL TO CONDENSING UNIT 24V CONNECTION BL YL YL WH...

Page 22: ...ERGENCY HEAT RELAY OPTIONAL COLOR CODES RD RED YL YELLOW BL BLUE BR BROWN OR ORANGE WH WHITE G C R HEAT PUMP UNIT WITH OPTIONAL HEAT KITS OF 10 kW AND BELOW C W1 W2 Y2 Y1 O G R TB 18 GA 7 WIRE O Y C W...

Page 23: ...conds after 24VAC is applied to G After 24VAC is removed from G the blower motor output is de energized after a delay of 65 seconds Normal Time Delays 60Hz 50Hz Turn On Delay 7 0 SEC 1 8 4 SEC 1 Turn...

Page 24: ...TDR 4 BROWN AND WHITE WIRES ARE USED WITH HEAT KITS ONLY 5 EBTDR HAS A 7 SECOND ON DELAY WHEN G IS ENERGIZED AND A 65 SECOND OFF DELAY WHEN G IS DE ENERGIZED 6 LOW VOLTAGE FIELD WIRING TO BE N E C CLA...

Page 25: ...ERVICING MULTIPLE POWER SOURCES MAY BE PRESENT FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE PERSONAL INJURY OR DEATH WARNING 3 Phase Heat Kit Wiring is subject to change Always refer to the wiring diagr...

Page 26: ...at con tain corrosive chemicals including but not limited to chlo rine and hydroxides should not be used AIR HANDLER AIR HANDLER HOMEOWNER S ROUTINE MAINTENANCE RECOMMENDATIONS An alternate cleaning m...

Page 27: ...27 THIS PAGE LEFT BLANK INTENTIONALLY...

Page 28: ...Though not required to get the protection of the standard warranty registering your product is a relatively short process and entitles you to additional warranty protection except that failure by Cali...

Reviews: