IMPORTANT —
This Document is customer property and is to remain with this unit.
Please return to service information pack upon completion of work.
EMI/EFI Air Handler Kit
Model:
BAYAHEMIKIT001A
Used With:
EMI/EFI Air Handler Motor
BAYAHEMIKIT001A KIT COMPONENTS
See Figure 1
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
SERVICE
INSTALLER'S
GUIDE
APPLICATION:
The EMI/EFI Air Handler Kit may be used on any air handler
unit with a CTM or variable speed motor. This Kit helps to
reduce the emitted noise generated when running these
motors.
18-GJ84D1-1A-EN
FIGURE 1
s
s
WARNING
!
The cabinet must have an uninterrupted or unbroken
ground according to National Electrical Code, ANSI/NFPA
70 - "latest edition" and Canadian Electrical Code, CSA
C22.1 or local codes to minimize personal injury if an
electrical fault should occur.
Failure to follow this warning could result in an electrical
shock, fire, injury, or death.
DISCONNECT POWER BEFORE SERVICING
WARNING
EMI Kit BAYAHEMIKIT001A
ITEM # Part Number
Part Description
Qty
1
D806151
TEM Male/Female Harness
1
2
D806153
TAM / GAM
Male/Female Harness
1
3
D806180P01
In-line EMI Filter (Schaffner)
1
4
D806121P01
Bracket, In-line EMI Filter
1
5
D804964P08
Gasket for back of Bracket
1
6
D806181P01
Ferrite Beads
2
7
D905103P01
#10 x 3/8" Cutting Screws
2
8
D804271P01
#8 x 1/2" Screws
2
9
D803499P01
#8 x 1/2 Cutting Screws
2
10
C107736P07
Cable Ties
4
11
18-GJ84D1-1A-EN Installation Instructions
1
12
D806182P01
Wiring Diagram
1
13
D806182P02
Wiring Diagram
1
14
D806182P03
Wiring Diagram
1
s
s
WARNING
!
Disconnect power to the unit before removing the blower
or coil door.
Failure to follow this warning could result in personal in-
jury from moving parts.
1
2
3
4
5
6
7
8
9
10
s
s
WARNING
!
Prevent all wires from touching any hot surfaces.
Failure to follow this warning could result in dangerous
operation, serious injury, death or property damage.