121022 v1.02-RiA
Operating instructions SG-RS 309-2
Page 23/23
Technical data
SG-RS 309-2
24 to 36 V DC
Signal output M1 / M2
EN 60947-5-1: Utilisation category
DC-12: U
S
/ 100 mA
Switching voltage
U
S
− 0.7 V
Switching current (max.)
100 mA
Switching current (min)
> 0 mA
Line length (max.)
10 m
Mechanical operating conditions
Cable terminals
6× 4-pin
Solid wire
1× 1.5 mm
2
or 2× 0.5 mm
2
Wire without sleeve
1× 1.5 mm
2
or 2× 0.75 mm
2
Wire with sleeve
without plastic sleeve
1× 1.5 mm
2
or 2× 0.34 mm
2
with plastic sleeve
1× 0.5 mm
2
or TWIN 0.5 mm
2
IEC 60529: Degree of protection
IP20
EN 50124: Pollution degree
PD2
Max. humidity (23 °C)
95%
EN 50125: Class of altitude range
A1
Operating temperature
−40 to +70 °C
Storage temperature
−25 to +70 °C
EN 50155:
Operating temperature class
OT3
Temperature change class
H1
EN 45545-2: suitable for
Hazard level
HL3
Set of requirements
R24
2006/42/EC and UK S.I. 2008 No. 1597:
Emission sound pressure level
< 70 dB(A)
EN 61373: Shock and vibration
Category 1, class B
Vibration fatigue limit
Frequency range
10 to 55 Hz
Amplitude
0.15 mm
Cycles per axis
10
Protective coating
Yes
Dimensions (W × H × D)
17.5 × 99 × 114.5 mm
Weight
115 g