INSTALLATION INSTRUCTIONS
STEP 1
SKYMAXX Model
Roof Opening
00-97000i, 00-97100i
00-97010i, 00-97110i
700 mm x 500 mm
Refer to the above table for
roof size opening. If you are
replacing another type already installed, remove the old
existing roof vent. Remove all old roof sealant for a
minimum of 5 cm (2 inches) entirely around the roof
opening.
STEP 2
Prior to installing the
SKYMAXX ROOFLIGHT
over the
roof opening, apply
a continuous strip of a flexible non-
hardening sealing compound (e.g. SikaLastomer-710) to
the underside of the flange in the grooved space.
CAUTION!
When installing your MAXXAIR
ROOFLIGHT, only use a caulking/sealant compatible
with the flange (plastic product) and the roof surface.
DO NOT use materials containing solvents such as or
similar to Xylene, Toluene, Methyl Ethyl Ketone (MEK),
Acetate or Acetone as they can damage the flange.
Also, Polysulfide (Thiokol) type sealants must be
avoided.
If in doubt, please contact the manufacturer of your
caravan for further information.
STEP 3
Insert the
SKYMAXX ROOFLIGHT
into the roof opening
with the hinged section facing the front of the vehicle
with the ceiling flange centered in the opening. Press
down on the flange to compress the sealant to seal to
the roof.
STEP 4
After the
SKYMAXX ROOFLIGHT
has been installed,
remove the excess sealant that may have squeezed out.
Using a sealer such as Dicor self-leveling lap sealant or
similar caulking, apply a bead (approximately 5 mm dia.)
along the outside edge of the flange all the way around
the rooflight.
THIS COMPLETES THE ROOF TOP PORTION OF THE INSTALLATION