background image

10

OPERATION GUIDE -  4 KEY WALL CONTROL

FOR MAXXFAN

® 

Deluxe

 

Models 8751K • 8951K

OPTIONAL FOR MAXXFAN

® 

Deluxe

 

Models 5100K, 5101K, 5301K, 6200K, 6201K, 6401K

VENT

OPEN

FAN ON

1-2-3-4

FAN OFF

VENT

CLOSE

OPERATION OF 4 KEY WALL CONTROL

FAN ON

1-2-3-4

Turns the fan motor ON at 

the last selected speed and 

OPENS the Vent Lid.

When Fan is running, cycles 

through four (4) fan Speeds. 

 

Once HIGH Speed is reached, 

the fan motor cycles back to LOW 

Speed.

FAN 

OFF

Turns the Fan Motor OFF and CLOSES the Vent Lid

VENT

OPEN

OPENS the Vent Lid

Fan motor remains in previous 

state

VENT

CLOSE

CLOSES the Vent Lid

Fan motor remains in previous 

state.  If fan motor is ON, the 

MAXXFAN enters Ceiling Fan 

Mode

OPERATION OF 1-SWITCH WALL CONTROL

FAN 1-2-3

Turns the fan motor ON at the last 

selected speed and OPENS the 

Vent Lid.

When Fan is running, select LOW, 

MEDIUM or HIGH Speed.  Once 

HIGH Speed is reached, the fan 

motor cycles back to LOW Speed.

FAN OFF

Turns the Fan Motor OFF

OPERATION GUIDE -  

1-SWITCH WALL CONTROL

FOR USE WITH MAXXFAN

® 

Deluxe MANUAL OPENING Models

5100K, 5101K, 5301K, 6200K, 6201K

OPERATION GUIDE -  

2-SWITCH WALL CONTROL

FOR USE WITH MAXXFAN

® 

Deluxe ELECTRIC OPENING Models

7000K, 7001K, 7500K, 7501K, 8000K, 8001K, 8500K, 8501K

CONTROL

DESCRIPTION

FAN 1-2-3

Turns the fan motor ON at 

the last selected speed and 

OPENS the Vent Lid.

When Fan is running, select 

LOW, MEDIUM or HIGH 

Speed.  Once HIGH Speed is 

reached, the fan motor cycles 

back to LOW Speed.

FAN OFF

Turns the Fan Motor OFF and CLOSES the Vent Lid

VENT 

OPEN

OPENS the Vent Lid

Fan motor remains in previous 

state

VENT 

CLOSED

CLOSES the Vent Lid

Fan motor remains in previous 

state.  If fan motor is ON, the 

MAXXFAN enters Ceiling Fan 

Mode

Summary of Contents for MAXXFAN Deluxe 5100K

Page 1: ...e outer rear edge The MAXXFAN is designed for a minimum roof thickness of 1 1 8 to a maximum of 6 1 2 If your roof thickness is less than 1 1 8 build additional thickness at the ceiling opening using...

Page 2: ...Silicone II non paintable used for outdoor applications have proven to be suitable for this installation If in doubt please contact the manufacturer of your RV for further information STEP 2 Apply Se...

Page 3: ...essary The Garnish ring should be cut 1 4 to 1 2 longer than the dimensions measured at each corner In Picture 6 below the installation measures 3 1 2 from the ceiling this is an example only to the C...

Page 4: ...der the round insect screen frame Your serial number may or may not be located in the same position as referenced in the above image Reference your operating guide Rotate the four retaining knobs 180...

Page 5: ...G FAN MODE With the fan motor running close the Vent Lid to enter Ceiling Fan Mode The fan motor will continue to run and circulate air within the RV cabin SERIAL NUMBER LABEL The serial number label...

Page 6: ...rating Knob KEYPAD CONTROLS Use Keys on Keypad to control MAXXFAN functions see descriptions on next page NOTE IR Sensor not on all models INSECT SCREEN RETAINER KNOB Rotate all 4 knobs 1 2 turn to re...

Page 7: ...emperature was entered or you wish to change a previous set temperature press the HOLD TO SET key for more than 3 seconds and you will hear one long beep and the thermostat will be reset to 78 F To fu...

Page 8: ...de close the vent lid and shut off the fan motor THERMOSTAT SET TEMPERATURE TEMP Press this button to increase the Set Temperature for Auto Mode TEMP Press this button to decrease the Set Temperature...

Page 9: ...Temperature for Auto Mode TEMP Press this button to decrease the Set Temperature for Auto Mode NOTE The thermostat temperature range is from 29 F to 99 F or 2 C to 37 C To change from Fahrenheit to C...

Page 10: ...motor ON at the last selected speed and OPENS the Vent Lid When Fan is running select LOW MEDIUM or HIGH Speed Once HIGH Speed is reached the fan motor cycles back to LOW Speed FAN OFF Turns the Fan...

Page 11: ...FAN Deluxe Models 7001K 7501K 8001K 8501K 11 FAN ON OFF OPEN CLOSE IN OUT AUTO HOLD TO SET 78 F OPERATION OF 6 KEY WALL CONTROL FAN ON OFF Turns the fan motor ON at the last selected speed and OPENS t...

Page 12: ...or additional product information please visit www AIRXCEL com AIRXCEL INC RV Products Division MAXXAIR 3050 N St Francis St Wichita KS 67219 316 832 3400 reinventing comfort PLACE CONSUMER LABEL HERE...

Reviews: