OPERATION OF 5 KEY WALL CONTROL

FAN

ON/OFF

Turns the fan motor ON at the last selected speed and 

OPENS the Vent Lid.  Turns the fan motor OFF and 

CLOSES Vent Lid.

Pressing this key when in AUTO mode will cause the fan to 

exit AUTO mode.

AUTO

Puts the fan in AUTOMATIC thermostat mode.  

Vent lid will automatically open and fan will turn on to cool RV 

when set temperature is reached.  Once RV is cooled down, 

fan will turn off and vent lid will close.  Thermostat is set to last 

selected temperature (memory function).  Green LED will light 

to indicate MAXXFAN is in AUTO mode.  Hold key for three (3) 

seconds to reset thermostat temperature to 78°F, use (+) & (-) 

keys to adjust set temperature up or down.  Press ON/OFF key 

to exit AUTO mode.

Adjusts the fan speed or thermostat set temperature.

When fan is on in MANUAL mode: adjusts fan speed up or 

down from 10% to 100% (10 speeds).  When fan is in AUTO 

mode: adjusts thermostat set temperature up or down by 1°F 

per key press.

OPEN/

CLOSE

OPENS and CLOSES the motorized Vent Lid.

Allows the vent lid to be open or closed with the fan motor on 

or off.  Close vent lid with fan motor running in Manual mode 

to enter Ceiling Fan Mode.

FAN

ON/OFF

OPEN/

CLOSE

AUTO

HOLD TO

SET 78°F

OPERATION GUIDE -  5 KEY WALL CONTROL

OPTIONAL FOR MAXXFAN

® 

Deluxe

 

Models 7001K • 7501K • 8001K • 8501K

11

FAN

ON/OFF

OPEN/

CLOSE

IN / OUT

AUTO

HOLD TO

SET 78°F

OPERATION OF 6 KEY WALL CONTROL

FAN

ON/OFF

Turns the fan motor ON at the last selected speed and 

OPENS the Vent Lid.  Turns the fan motor OFF and 

CLOSES Vent Lid.

Pressing this key when in AUTO mode will cause the fan to 

exit AUTO mode.

AUTO

Puts the fan in AUTOMATIC thermostat mode.  

Vent lid will automatically open and fan will turn on to cool RV 

when set temperature is reached.  Once RV is cooled down, 

fan will turn off and vent lid will close.  Thermostat is set to last 

selected temperature (memory function).  Green LED will light 

to indicate MAXXFAN is in AUTO mode.  Hold key for three (3) 

seconds to reset thermostat temperature to 78°F, use (+) & (-) 

keys to adjust set temperature up or down.  Press ON/OFF key 

to exit AUTO mode.

Adjusts the fan speed or thermostat set temperature.

When fan is on in MANUAL mode: adjusts fan speed up or 

down from 10% to 100% (10 speeds).  When fan is in AUTO 

mode: adjusts thermostat set temperature up or down by 1°F 

per key press.

OPEN/

CLOSE

OPENS and CLOSES the motorized Vent Lid.

Allows the vent lid to be open or closed with the fan motor on 

or off.  Close vent lid with fan motor running in Manual mode 

to enter Ceiling Fan Mode.

IN/OUT

Reverses fan motor for either INTAKE or EXHAUST air 

direction.

OPERATION GUIDE 6 KEY WALL CONTROL

FOR MAXXFAN

® 

Deluxe

 

Models 8700K • 8900K

OPTIONAL FOR MAXXFAN

® 

Deluxe

 

Models 7000K, 7500K, 8000K, 8500K

Summary of Contents for MAXXFAN Deluxe 5100K

Page 1: ...e outer rear edge The MAXXFAN is designed for a minimum roof thickness of 1 1 8 to a maximum of 6 1 2 If your roof thickness is less than 1 1 8 build additional thickness at the ceiling opening using...

Page 2: ...Silicone II non paintable used for outdoor applications have proven to be suitable for this installation If in doubt please contact the manufacturer of your RV for further information STEP 2 Apply Se...

Page 3: ...essary The Garnish ring should be cut 1 4 to 1 2 longer than the dimensions measured at each corner In Picture 6 below the installation measures 3 1 2 from the ceiling this is an example only to the C...

Page 4: ...der the round insect screen frame Your serial number may or may not be located in the same position as referenced in the above image Reference your operating guide Rotate the four retaining knobs 180...

Page 5: ...G FAN MODE With the fan motor running close the Vent Lid to enter Ceiling Fan Mode The fan motor will continue to run and circulate air within the RV cabin SERIAL NUMBER LABEL The serial number label...

Page 6: ...rating Knob KEYPAD CONTROLS Use Keys on Keypad to control MAXXFAN functions see descriptions on next page NOTE IR Sensor not on all models INSECT SCREEN RETAINER KNOB Rotate all 4 knobs 1 2 turn to re...

Page 7: ...emperature was entered or you wish to change a previous set temperature press the HOLD TO SET key for more than 3 seconds and you will hear one long beep and the thermostat will be reset to 78 F To fu...

Page 8: ...de close the vent lid and shut off the fan motor THERMOSTAT SET TEMPERATURE TEMP Press this button to increase the Set Temperature for Auto Mode TEMP Press this button to decrease the Set Temperature...

Page 9: ...Temperature for Auto Mode TEMP Press this button to decrease the Set Temperature for Auto Mode NOTE The thermostat temperature range is from 29 F to 99 F or 2 C to 37 C To change from Fahrenheit to C...

Page 10: ...motor ON at the last selected speed and OPENS the Vent Lid When Fan is running select LOW MEDIUM or HIGH Speed Once HIGH Speed is reached the fan motor cycles back to LOW Speed FAN OFF Turns the Fan...

Page 11: ...FAN Deluxe Models 7001K 7501K 8001K 8501K 11 FAN ON OFF OPEN CLOSE IN OUT AUTO HOLD TO SET 78 F OPERATION OF 6 KEY WALL CONTROL FAN ON OFF Turns the fan motor ON at the last selected speed and OPENS t...

Page 12: ...or additional product information please visit www AIRXCEL com AIRXCEL INC RV Products Division MAXXAIR 3050 N St Francis St Wichita KS 67219 316 832 3400 reinventing comfort PLACE CONSUMER LABEL HERE...