Problem
Possible Cause
Solution
Capstan does not rotate.
No electric power to controls.
Make sure the isolator switch for the
capstan controls is ON.
Check the fuse on power supply to
controls.
Make sure the wiring is correct and
check it for damage.
Check the power supply to controls
from the source, step by step, and
identify the point where it stops.
Incorrect or incomplete wiring.
Check wiring against diagrams
supplied.
No power supply to the capstan.
Check power supply lines.
Check main isolator switch.
Check hydraulic pump.
Capstan is not able to pull the
specified load.
Hydraulic relief valve not set
correctly.
Check valve setting.