14
4.3 Mount the PC4164-RS and Wireless Devices
Do not permanently mount the PC4164-RS until you have tested reception with all
the wireless devices (see sections 4.1 and 4.2). Once you have done this and have a
good location, mount the PC4164-RS:
1. Remove the four screws that attach the PC4164-RS to the plastic cabinet.
2. Pull the Combus wires through the hole at the back of the cabinet.
3. Mount the cabinet securely to the wall.
4. Reattach the PC4164-RS to the mounted cabinet using the four mounting screws.
Mount the WLS904, WLS905, WLS906 and WLS907 Devices
If you have conducted the placement test described in section 4.1 and got 3 “Good”
or “Fair” results in a row for each device, you can mount the wireless devices. See
the Installation sheet for each device for mounting instructions.
4.4 Battery Test For WLS908 Panic Pendants
Panic Pendants cannot be tested using the module placement test, or the walk test.
You must assign panic pendant zones to one or more partitions before you can test
the Panic Pendants. Follow these steps to test Panic Pendants:
1. Begin testing when your PC4010/4020 system is in the ready state and the
LCD keypad Ready light is on.
2. Go to a partition to which the pendant is assigned.
NOTE
: You can only view the Panic Pendant test result on a partition LCD keypad. To
view the test result on a global LCD keypad, you must “loan” the keypad to the
partition before you begin the test. See your PC4010/4020 Installation Manual for
information on global and partition keypads.
3. Press and hold the small middle button on the pendant marked “Test” for two
seconds.
4. If the pendant’s battery is low, the LCD keypad’s Trouble light will turn ON
and the keypad will give a series of continuous beeps.
The user should also perform this test when they perform the weekly system test.
NOTE
: If a low battery condition is detected, you must immediately replace the unit.
T E S T I N G & M O U N T I N G D E V I C E S