![MaxStream 9XTend Product Manual Download Page 36](http://html1.mh-extra.com/html/maxstream/9xtend/9xtend_product-manual_1745552036.webp)
9XTend™
OEM
RF
Module
–
Product
Manual
v1.2.4
©
2005
MaxStream,
Inc.
Confidential
&
Proprietary
36
WR (Write) Command
<(Special)> WR Command writes configurable
parameters to the module’s non-volatile memory
(Parameter values remain in the modem’s
memory until overwritten by future use of WR Command).
AT Command: ATWR
Binary Command: 0x08
If changes are made without writing them to non-volatile memory, the module reverts back to
previously saved parameters the next time the module is powered-on.
WS (Sticky Warning Numbers) Command
AT Command: ATWS
Parameter Range (read-only): 1 – 8
Number of bytes returned: 1
<Diagnostics> WS Command reports the warning
numbers of all warnings which have been active
since the last use of WS or WN command,
including any warnings which are currently
active. No further information is shown.
This command also resets all non-zero warning counts, except for warnings that are presently
active, which are set to 1.