Maintenance and Repair
Introduction
This section covers the tests which should be undertaken prior to customer handover. All of the
following tests can be carried out without having to gain access to the interior of the radio.
Recommended Test Equipment
The alignment and performance test procedures assume the use of the following equipment. The
functions of most of the equipment may be found in a “Communications Test Set”. This type of
equipment is available from a number of test equipment manufacturers.
Throughout this book, reference will be made to the use of the Communications Test Set. Where
applicable, the equivalent discrete item of test equipment may be used. For example, if
measuring power, a stand-alone power meter and a dummy load could be used instead of the
Test Set.
Discrete Test Equipment
RF Signal Generator
RF Power Meter
RF Frequency Counter
Spectrum Analyzer and notch filter (optional)
Audio Signal Generator
Audio Power Meter
SINAD Meter
Modulation Meter
Oscilloscope
Voltmeter
DC Power Supply, 0 - 15V 5A min.
Combined Equipment
Communications Test Set (e.g. HP 8920B,
Stabilock 4040 or similar).
Accessories
SP -1402
Note:
Use fig.1 as a suggested connection diagram to connect up the recommended discrete test
equipment.
Summary of Contents for SP-1102
Page 1: ...Service Manual SP 1402 Page 1 of 35 SP 1402 Service Manual...
Page 18: ...Service Manual SP 1402 Page 18 of 35 Alignment Alignment drawings required Fig 3...
Page 29: ...Service Manual SP 1402 Page 29 of 35 Schematics and PCB layout Index...
Page 30: ...Service Manual SP 1402 Page 30 of 35 Schematics and PCB layout Index...
Page 31: ...Service Manual SP 1402 Page 31 of 35 Schematics and PCB layout Index...
Page 32: ...Service Manual SP 1402 Page 32 of 35 Schematics and PCB layout Index...
Page 34: ...Service Manual SP 1402 Page 34 of 35 Parts List...