Multimax_user manual_v.4.0.4 July. 11, 2018 53/139
Confidential
Mode
Select from “ON
-
OFF” or “Counter”.
ON-OFF: DI interface support ON and OFF mode (high or low level electrical)
trigger DI alarm. The mode default to ON, and OFF mode is available only
when enabling the inversion feature
ON
—
Under this mode, DI alarm status will be triggered to ON when DI
interface open from GND or input a high level electrical (logic 1), on the
contrary DI alarm status will be trigged to OFF when DI interface connect to
GND or input a low level electrical (logic 0)
OFF
—
Under this mode, DI alarm status will be triggered to ON when DI
interface connect to GND or input a low level electrical (logic 0), on the
contrary DI alarm status will be trigged to OFF when DI interface open from
GND or input a high level electrical (logic 1)
Counter: Event counter mode
ON-OFF
Inversion
Click the toggle button to enable/disable this option. Enable to set DI mode as OFF
mode.
OFF
Threshold Value
Set the threshold vale. It will trigger alarm when event counter reaches this figure.
After triggering alarm, DI will keep counting but not trigger alarm again. Enter 0 to
65535 digits. (0=will not trigger alarm)
Note
: This option is only available when DI under the “Counter” mode.
Null
Note:
It defaults as high alarm, while turns to l
ow alarm after enabling the “Inversion” button.
3.6.7.2 - DO
Click the right-most
to enter the DO configuration
Summary of Contents for multimax+
Page 1: ...Dual Port Dual SIM Industrial Cellular Router 4G User Manual 1 04...
Page 7: ...Multimax_user manual_v 4 0 4 July 11 2018 7 139 Confidential...
Page 10: ...Multimax_user manual_v 4 0 4 July 11 2018 10 139 Confidential 1 4 Dimensions...
Page 28: ...Multimax_user manual_v 4 0 4 July 11 2018 28 139 Confidential...
Page 89: ...Multimax_user manual_v 4 0 4 July 11 2018 89 139 Confidential...
Page 120: ...Multimax_user manual_v 4 0 4 July 11 2018 120 139 Confidential...