68 MULTIMAX USER GUIDE
Strip: Data in the buffer is first stripped of the delimiter before
being transmitted.
Local Port @
Modbus
Enter the Local port for Modbus.
0
Attached serial
device type
@Modbus
Select From “Modbus RTU slave”, “Modbus ASC
Ⅱ
slave”,
“Modbus RTU master” and “Modbus ASC
Ⅱ
master”.
Modbus RTU slave: router connects to slave device which
works under Modbus RTU protocol.
Modbus ASC
Ⅱ
slave: router connects to slave device which
works under Modbus ASC
Ⅱ
protocol.
Modbus RTU master: router connects to master device which
works under Modbus RTU protocol.
Modbus ASC
Ⅱ
master: router connects to master device which
works under Modbus ASC
Ⅱ
protocol.
Attached
serial
device
type
@Modbus
Modbus Slave @
Modbus
Add the Modbus slaves which will be polled by Modbus master
(router). This section only displayed when you select “Modbus
RTU master” or “Modbus ASC
Ⅱ
master” in “Attached serial
device type”.
Null
Slave Address
This connection is usually used to connect to the Modbus slave
devices which as TCP server. Enter IP address of the TCP server.
Null
Slave Port
Enter the port number of TCP server.
Null
ID
Enter the ID number of TCP server.
Null