CAUTION: 

This product is sensitive to Electrostatic Discharges (ESD). Take precautions while handling the product by using 

proper grounding straps at all times. 

PHYSICAL SPECIFICATIONS 

Length:

 

76 mm  (3.00 in) 

Width:

 

48 mm  (1.90 in) 

Height: 

17 mm  (0.67 in) 

Weight: 

34 g 

(1.20 oz) 

Readers: 

1

 

Supervised Inputs: 

Relay Outputs: 

This Freedom device is tested to:

Electrical: UL294

EMI Radiation: FCC Part 15 Class B

INSTALLATION REQUIREMENTS 

Freedom Bridges should only be installed in 

dry

non-condensing 

environments. The ambient temperature of the 

environment should range between 

-40°C 

and 

50°C

Freedom Encryption Bridges should only be mounted to 

non-conductive

 surfaces. Incorrect mounting may short-circuit 

the electronics, which will cause it to malfunction. 

DC power, reader, input contact, and output device wires should be between 16-28 AWG. They should also be stripped 
5.5mm to sufficiently fit the terminal blocks and ensure that they do not come in contact with each other. 

INSTALLATION PROCEDURE 

For each of the following steps, be sure to reference the wiring diagram on page 2 for additional details: 

1. Connect an 

RS-485 Reader

 to the 

RS-485 Reader Input

 on the Freedom Bridge.  

The selection of 2-wire or 4-wire

operation is done via UDP configuration, as is the baud rate (nominally 57600)

a.

A 2-wire RS-485 reader must be connected with a 4-position connector for +12, A, B, 0v, leaving the other 2 pins (R- and R+)

empty.  Connect the +12, A, B and t

he reader 

shield wire 

to 0v terminals on the 

Reader Input

.

b.

A 4-wire RS-485 requires a 6-position connector for +12, T-, T+, 0v, R-, R+, where T- means Transmit Inverted signal, and R+

means Receive non-inverted signal.

2.

Any unused wires on the reader must be evenly snipped and have their tips insulated using electrical tape or
equivalent. The shield wire on the reader must also be completely insulated to prevent ground loops.

3.

If you have any 

supervised input contacts

, wire them to the 

Digital Contact Inputs

 using Method 1 or Method 2.

4.

If you have any 

non-supervised input contacts

, wire them to the 

Digital Contact Inputs.

5.

If you have a 

relay output contact

, wire it to the 

Relay Output

.

6.

Supply power to the Freedom Bridge using either or both of the following methods:

a. Wire 

12 - 16Vdc 

power, up to 

400mA

, directly to the       terminal on the Freedom Bridge. 

b. Connect a Cat5, 5e, or Cat6 cable from any non-PoE port on an Ethernet Switch to the RJ-45 port on the

Freedom Bridge.

Note:

 Ethernet only supports a 

maximum cable segment length

 of 

100m (328ft)

. Greater lengths can be achieved 

by adding switches or repeaters every 100m (328ft). 

7. To add the Freedom Bridge to a Freedom Server and configure it, refer to the Freedom Version 8 Software Guide.

flashing green “

Ready” LED light on the Freedom Bridge circuit board indicates that the bridge is attempting to connect to the server. 

solid green “

Ready” LED light indicates that the Freedom Bridge has established a connection to the server and is ready to use. 

50-40-

485

 

            

F

REEDOM 

RS485

 

B

RIDGE

™ 

Installation Guide

EM-40-1HA 

Base Plate Mounting 

Dim 

mm 

in 

116.07 

4.57 

78.74 

3.10 

15.24 

0.60 

85.59 

3.37 

10.16 

0.40 

58.42 

2.30 