LIFT CORPORATION
Sht. 18 of 56 DSG#
M-16-32
Rev.
C
Date: 08/13/19
ROUTING POWER CABLES - Continued
5.
Cut positive
(+)
cable to the length required to
reach the
AUX
terminal of the circuit breaker
(FIGS. 18-2 and 18-3),
without putting strain
on the connection. Install copper lug (Kit item)
(FIGS. 18-1 and 18-2)
. Then, connect to
AUX
terminal on 150A circuit breaker
(FIGS. 18-2
and 18-3)
.
6.
Cut remaining positive
(+)
cable long enough
to reach from the circuit breaker
BAT
terminal
to the positive
(+)
battery terminal
(FIGS. 18-2
and 18-3)
without putting strain on the con-
nection. Install copper lugs (Kit item) on both
ends of cable
(FIGS. 18-1 and 18-2)
. Then,
connect cable to
BAT
terminal on 150A circuit
breaker
(FIGS. 18-2 and 18-3)
and positive
(+)
terminal on battery
(FIG. 18-2)
.
PLACING COPPER LUG & HEATSHRINK
TUBING ON POWER CABLE
FIG. 18-1
COPPER LUG
POWER CABLE
(BARE WIRE END)
HEATSHRINK
TUBING
TYPICAL POWER CABLE WITH
COPPER LUG INSTALLED
FIG. 18-2
7.
Cut negative
(-)
cable to length required to
reach negative
(-)
battery terminal
(FIG. 18-
2)
without putting strain on the connection.
Install copper lug (Kit item)
(FIGS. 18-1 and
18-2)
. Then, connect cable to negative
(-)
terminal on battery
(FIG. 18-2)
.
POWER CABLE CONNECTIONS
TO 150A CIRCUIT BREAKER
FIG. 18-3
CONNECT SHORT POS
(+) CABLE TO BATTERY
CONNECT LONG POS (+)
CABLE FROM LIFTGATE