Photocell (Thru-Beam) CLOSING Direction
Single Gate Operator
Transmitter
(TX)
Receiver
(RX)
Single
Operator
CLOSING direction Thru-Beam
Gate Closed
emx irb-mon
IMPORTANT:
Photocells MUST be powered
by Matrix III or they will
NOT
be
MONITORED
.
12VDC OUT
Polarity does
NOT
matter
NC
NO
NC
COM
COM NO
RX
POWER
INPUT
JUMPER
EARTH
GND
SENSITIVITY
TX
POWER INPUT
TRANSMITTER
BOARD (TX)
ON
DIP
1
2
3
4
RECEIVER
BOARD (RX)
Sensitivity Adjustment:
If the photocell does not
respond to an obstruction,
lower the sensitivity by
turning adjustment
counter-clockwise.
Transmitter (TX)
Receiver (RX)
PHOTO CLS NC -
Normally Closed
GND -
Common
NO
Com
NC
Green
LED
To
PHOTO CLS NC
and
12VDC OUT
Input
To Matrix III
12VDC OUT
Input
TX
RX
Jumper
Green
LED
NOTE: To meet the UL 325 2018 standard, Type B1
Non-Contact sensor entrapment protection device
MUST be MONITORED by the gate operator.
Installation Steps:
1.
Set DIP-switches on receiver.
2.
Install jumper on receiver.
3.
Wire Matrix III
12VDC OUT
power to receiver.
4.
Wire
PHOTO CLS NC
to receiver photocell
NC.
Wire Matrix III
GND
to
receiver photocell
COM.
5.
Wire
12V
Matrix III
power to transmitter.
6.
Align photocells.
7.
Adjust sensitivity on receiver.
Jumper
MUST
be on Com-NC.
DIP-switches:
1, 2, 3 are
OFF.
Switch 4 is
ON
If trouble occurs, try
turning switch 4 OFF.
NOTE:
Power must be
cycled when switches
are changed.
IMPORTANT:
Photocells
MUST
be
in alignment or fault will occur.
Green LED will remain
ON
receiver
when in proper alignment.
OPEN ONLY
NC
OPEN ONLY
10K
PHOTO CLS
NC
OPEN/CLS
NC
GND
12VDC OUT
GND
CLS ONLY
10K
OPEN/CLS
10K
12VDC OUT
UL SENSOR N.C.
UL SENSOR 10K
P
NSOR N.C
P
NSOR N.C
P
SOR N.
P
SOR N
SOR N
SOR N
OR N
OR N
OR
UL SEN
N
UL SEN
UL SEN
UL SEN
UL SE
UL SE
UL SE
L SE
L S
29
UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7