EXIT PWR
ALARM
POWER /
SOLAR IN
BATTERY
INPUT
OPENING
CLOSING
CLOSING
OPENING
ERD
OBD PORT
BLACK BOX
PROGRAMMING
SOLAR MODE
PROGRAM
MOTOR
OVER
LOAD
ERD
MOTOR
OVER
LOAD
MAX
OFF
MAX
SENSE
MAX
SENSE
BATTERY
BACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
GATE SPEED
MAG
LOCK
UL
ENTRAP
PRIMARY/
SECONDARY
LINK
STOP
CLOSE
MOTOR
INPUTS
CLOSE
TIMER
MAGLOCK
DELAY
JOG
BATTERY
TEST
INPUT
ERROR
BATTERY
BATTERY
IN USE
REPLACE
BATTERY
LEAVE
CLOSED
LEAVE
OPEN
OPEN
1 TIME
BATTERY VOLTAGE
E
2/
1
F
RESET /
MANUAL
RELEASE
ID
PLUG
LINK
OK
MODULE
PORT
MOTOR
POSITION
INPUTS
SLIDER
LIMIT
SWING
LIMIT
GND
OPEN ONLY
NC
OPEN ONLY
10K
PHOTO CLS
NC
OPEN/CLS
NC
GND
12VDC OUT
GND
GND
GND
GND
GND
GND
JOG RIGHT
JOG LEFT
TAMPER IN
TAMPER NO
GATE DISABLE
MANUAL RELEASE
KEYPAD / CARD
GND (-)
(+)
GND
GND
MAX OPEN
FIRE DEPT
RADIO GND
RADIO SIGNAL
STRIKE
CLOSE COM
COM
STOP
OPEN
CLS ONLY
10K
OPEN/CLS
10K
12VDC OUT
NO
COM
NC
ID PLUG
ERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOP PWR
OFF
PRIMARY
LEFT
ON/OFF
BATTERY
RIGHT
SECONDARY
ON
QUICK
CLOSE
OPEN
LEFT
OPEN
RIGHT
GATE
OFF
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
MIN
MIN
MAX
MAX
ON
OFF
2.5 sec
1.5 sec
FAULTS
OPERATOR
MATRIX III
OFF
OFF
3
1
14
16
MIN
16
MIN
12
9
7
3
1
14
12
9
7
UL SENSOR N.C.
UL SENSOR 10K
POWER
MODE A
MODE B
EXIT LOOP
LOOP
LOOP
CENTER
SAFETY
GATE OPEN
COM
GATE CLOSED
MIN
MATRIX III
SWING / SLIDE
Safety Opening Device
Safety Devices
Factory Wired
Factory Wired Plug
Factory Wired Plug
Factory Wired Plug
Factory Wired Plug
for SLIDE operator
Factory Wired Plug
Factory Wired Plug
Factory Wired Plug
Factory Wired Plug
External
Loop
Detector
External Loop
Detectors
Wire directly to
7-PIN terminal
Card Reader
Separate
power for
devices if required.
Keypad
Key Switch
Key Switch
Telephone Entry
Emergency OPEN
(Overrides gate
disable switch)
MAX OPEN
(Overrides gate
disable switch)
Emergency/Security Opening Devices
Normal
Opening
Devices
Dry Contact NO
Dry Contact NO
NO
NO
Radio Signal
Radio Signal
Radio Gnd
12 VDC
OR
24 VDC
Radio Power
250 mA Max.
4-Wire
Radio
3-Wire
Radio
Normal
Opening
Device
RS-485 Communication
Secondary Operator
Stop
Stop
Close
Open
Tamper NO
Tamper IN
Com
Com
Com
Gate Disable
Com
Gnd
Gnd
Gnd
Gnd
Gnd
Manual Release
Manually Releases
Slide
Gate
Gnd
Gnd
Gnd
NO
NC
Power
NC
Jog Left
Jog Right
External Alarm
Reset Button
Dry Contact
Security Device
PRESS
to RESET
ID Plug:
Specific for operator
type
REQUIRED
.
Maglock
Solenoid
Lock
Motion Sensor
External Jog Left/Right
Key Switch
Opening
Direction
Security
Camera
page 15
page 18
page 15
see page 17
see page 12
see page 12
see page 12
see page 12
see page 7-8
see page 6
see page 11
see page 10
3-Button Control Station
Dry Contact
Gate Disable Switch
ON
OFF
Security Devices
Security Device
Opening Device
Security
Devices
Entrapment Protection Devices
Safety Device
Normal Opening Device
Siren
Warning
Light
Power
Power
Power
Existing
Building
Alarm
System
Timer
Normally Closed
Photocells
Closing
Direction
Opening
Direction
Closing
Direction
10K
Sensing
Edges
IMPORTANT:
Sensing devices
MUST be powered by Matrix III or
they will
NOT
be
MONITORED
.
IMPORTANT:
Photocells
MUST
be in alignment or fault will occur.
GATE OPEN
GATE CLOSED
Gate Status
Monitoring Device
Power
Bi-parting gates using locks:
Primary gate opens
FIRST
. Install
lock accordingly to account for this.
ON
1
2
3
4
5
6
7
8
5 =
Opti
mum
Sens.
=
Increase S
ens.
=
Decr
ease
Sens.
DEFL
ECTOMETER
POW
ER
ON
= No
rmal
Power
OFF=
No Po
wer
LED INDIC
ATOR
S
DETE
CT
ON =
Detect
OFF= No
Detec
t
2 Hz Fl
ash=D
elay T
iming
SW1
SW
2 Fre
quenc
y
ON
ON =
Low
ON
OFF
= Med
ium-Low
OFF
ON =
Med
ium-High
OFF
OFF =
High
SW4
SW
5 Out
put B
ON
ON =
Puls
e on
Entry
ON
OFF
= B sa
me a
s A
OFF
ON
=
Pulse
on E
xit
OFF
OFF
= Loo
p Fau
lt
SW3
ON =
Fail Se
cure
OFF
= Fa
il Safe
SW6
ON
= 2
Second
Delay
OFF =
No
Delay
SW7
ON
= N
orma
l Pres
ence
OFF =
Infi
nite P
resen
ce
SW8
ON
= Se
nsitiv
ity Bo
ost
OFF
= N
o Sen
sitivit
y Boos
t
Loop
Faul
t
1 Flas
h = Op
en Loo
p
2 Flas
hes= S
horted
Loop
3 Flashes
=25
% chan
ge
of In
ductan
ce
Both
LED’s Flash
ing=
Curr
ent Lo
op Fa
ult
PWR
LED F
lashing
=
Prev
ious L
oop Fa
ult
EDI
Tel: 4
80.96
8.640
7
DEFLEC
TOM
ETE
R
SENS
RESET
POWER
DET
ECT
EDI
SEN
S
LMA1800
OPTIONS
1
2
3
4
5
6
7
8
ON
Plug-In Loop
Detectors
In-Ground Loop Connections
Loop Detector Rack
SAFETY
CENTER
EXIT
SAFETY
CENTER
EXIT
In-Ground Loops
Safety Loops
Wired in series
Safety
Loop
Safety
Loop
Exit
Loop
page 11
page 10
page 11
page 6
page 6
page 11
page 9
page 19
page 13
page 10
12V Power
Stand-Alone
Keypad
less than 200 mA
+
+
-
+
-
-
1700 FS
OR
P
3
2
UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7
d
wiring
overview