background image

gate disable feature

GATE DISABLE

ALL

GATE DISABLE


GATE DISABLE

 

IMPORTANT:

 It is 

NOT

GATE DISABLE

EXIT LOOP

Metal

Plate

GATE DISABLE

 

EXIT PWR

POWER /

SOLAR IN

BATTERY

INPUT

OPENING

CLOSING

CLOSING

OPENING

ERD

OBD PORT

BLACK BOX

PROGRAMMING

SOLAR MODE

PROGRAM

MOTOR

OVER

LOAD

ERD

MOTOR

OVER

LOAD

MAX

OFF

MAX

SENSE

MAX

SENSE

BATTERY

BACKUP MODE

ERD SENSITIVITY

MOTION CONTROL

OPEN

GATE SPEED

MAG

LOCK

UL

ENTRAP

PRIMARY/

SECONDARY

LINK

STOP

CLOSE

MOTOR

INPUTS

CLOSE

TIMER

MAGLOCK

DELAY

JOG

BATTERY

TEST

INPUT

ERROR

BATTERY

BATTERY

IN USE

REPLACE

BATTERY

LEAVE

CLOSED

LEAVE

OPEN

OPEN

1 TIME

BATTERY VOLTAGE

E

F

1/2

RESET /

ID

PLUG

LINK

OK

MODULE

PORT

MOTOR

POSITION

INPUTS

SLIDER

LIMIT

SWING

LIMIT

GND

OPEN ONLY 

NC

OPEN ONLY 

10K

PHOTO CLS 

NC

OPEN/CLS 

NC

GND

12VDC OUT

GND

GND

GND

GND

GND

GND

JOG RIGHT

JOG LEFT

TAMPER IN

TAMPER NO

GATE DISABLE

MANUAL

 RELEASE

KEYPAD / CARD

GND

(+)

GND

GND

MAX OPEN

FIRE DEPT

RADIO GND

RADIO SIGNAL

STRIKE

CLOSE COM

COM

CLS ONLY 

10K

OPEN/CLS 

10K

12VDC OUT

NO

COM

NC

ERROR

24VDC OUTPUT

12VDC OUTPUT

GND

GND

GND

LOOP PWR

OFF

PRIMARY

LEFT

ON/OFF

BATTERY

RIGHT

SECONDARY

ON

QUICK

CLOSE

OPEN

LEFT

OPEN

   RIGHT

GATE

OFF

1

2

3

4

5

6

7

8

9

10

MIN

MIN

MAX

MAX

ON

OFF

2.5 sec

1.5 sec

FAULTS

OPERATOR

MATRIX III

OFF

OFF

3

1

14

16

MIN

16

MIN

12

9

7

3

1

14

12

9

7

UL SENSOR N.C.

UL SENSOR 10K

POWER

EXIT LOOP

LOOP

LOOP

CENTER

SAFETY

GATE OPEN

COM

GATE CLOSED

MIN

MATRIX III

SWING / SLIDE

EX

PR

SECON

LINK

ELEASE

RD

GND

GND

OOP PWR

PRIMARY

SEC

EX

LOO

LOOP

CENTER

Y

CLOSING

E

PROGRAM

GATE

CL

OFF

MI

MAX

RESE

ON

OFF

GATE DISABLE

 

DISABLE

FIRE DEPT

MAX OPEN 

and

 RADIO 

GATE DISABLE

When GATE DISABLE is turned ON:

3 minutes BEFORE arming itself.

GATE DISABLE 

When FIRE DEPT/MAX OPEN gets activated:

GATE TAMPER

When RADIO Input gets activated: 

GATE TAMPER

after 3 min

GATE DISABLE

GATE DISABLE

ON

Wiring Gate Disable

18

UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7

d

Summary of Contents for MAX 1500 PRO

Page 1: ...TO UL STD 325 MAX 1500 PRO 2200 PRO UL CLASS I II III IV MAX F18 PRO UL CLASS III IV ONLY CERTIFIED TO CAN CSA STD C22 2 NO 247 SAFETY SENSORS REQUIRED CONFORMS TO UL STD 325 Installation Guide for MA...

Page 2: ...t lors de l ouverture et de la fermeture la barri re doit tre install e dans un endroit o la barri re et les structures avoisinantes sont suffisamment loign es l une de l autre Les barriers battantes...

Page 3: ...s un capteur de contact doit tre situ o il existe un risque de coincement ou d obstruction comme sur le bord d ouverture sur le bord de fermeture et sur les poteaux mont s sur l int rieur ou l ext rie...

Page 4: ...etest the gate operator properly can increase the risk of injury or death 4 V rifiez le fonctionnement de l ouvre barri re une fois par mois Le sens de la course DOIT s inverser lorsque la barri re en...

Page 5: ...ONLY ul 325 model classifications A Inherent entrapment protection system B1 Provision for connection of a non contact sensor photoelectric sensor or the equivalent B2 Provision for connection of a c...

Page 6: ...stalled where entrapment or pinch point exist A minimum of TWO entrapment protection sensors MUST be installed ONE in EACH direction of gate travel or operator will NOT function Physical Stops Install...

Page 7: ...ssing through the openings anywhere in the gate and in that portion of the adjacent fence that the gate covers in the open position all exposed pinch points are eliminated or guarded and guarding is s...

Page 8: ...325 Class of Operation MAX 1500 PRO 2200 PRO Class I II III IV MAX F18 PRO Class III IV ONLY Gate Type Vehicular Slide Gate Max Gate Length MAX 1500 PRO 25ft MAX 2200 PRO MAX F18 PRO 50ft Max Gate Wei...

Page 9: ...round to avoid flooding Concrete Depth Note The heavier the gate the deeper the concrete pad should be At least two feet recommended for heavier gate Secure gate operator to concrete pad with four 4 1...

Page 10: ...or is NOT parallel to gate Chain is NOT parallel to gate DO NOT mount chain bracket too high on gate NO NO YES YES YES YES Drive Gear NOTE The chain should sag no more than one 1 inch per 10 feet of t...

Page 11: ...75 7 5 7 5 6 75 Cover 1 5 4 5 6 5 8 625 12 75 Conduit Area Outside Property Inside Property Input Power Physical Stop Conduit Run Operator MUST be level Concrete Pad Check local building codes in your...

Page 12: ...heel Approx 1 5 Pulley Wheel Safety Cover Gate YES YES Modify Cover for Rear Mounting Position 16 5 Cut out cover between new hole and existing chain exit slot Make sure cuts are plumb with existing c...

Page 13: ...SLIDER AC IN FUSE 7 Amp POWER On Off www Max US com MAX Toroid 15 Amp Select Input Voltage 115VAC or 230VAC 1 1 5 V MAX Toroid Box DANGER HIGH VOLTAGE Additional Gang Box 2 ac input power Choose eithe...

Page 14: ...n ing pro te ction L I M I T S E N S O R E 1 2 Re pla ce Bat ter y ON OF F Bat ter y TES T Bat ter y Bat ter y IN Err or F Bat ter y Mo dul e THREE DO NOT 1 2 3 OPEN RIGHT OPEN LEFT MAX 1500 PRO MAX 2...

Page 15: ...TAMPER NO COM CLS ONLY 10K OPEN CLS 10K 12VDC OUT NO COM NC LEFT RIGHT OFF 2 5 sec 1 5 sec UL SENSOR N C UL SENSOR 10K entrapment protection wiring 5 Entrapment Protection Device Options and Locations...

Page 16: ...S NC GND 12VDC OUT GND CLS ONLY 10K OPEN CLS 10K 12VDC OUT UL SENSOR N C UL SENSOR 10K P NSOR N P NSOR P SOR P SOR SOR SOR OR OR OR O N C N N R R R R R R O N C N N N N R R R R O N C N N N N N R R R O...

Page 17: ...TS CLOSE TIMER MAGLOCK DELAY JOG BATTERY TEST INPUT ERROR BATTERY IN USE REPLACE BATTERY LEAVE CLOSED LEAVE OPEN OPEN 1 TIME BATTERY VOLTAGE E F 1 2 RESET MANUAL RELEASE ID PLUG LINK OK MODULE PORT MO...

Page 18: ...ter clockwise to reduce gate sensitivity while testing ERD until desired results is attained LED remains OFF for all but position 1 IMPORTANT When satisfied with ERD adjustment cycle the gate 3 or 4 t...

Page 19: ...Rack SAFETY CENTER EXIT In Ground Loops loops loop detectors 9 matrix III settings 10 Maglock Delay Set to OFF Close Timer 1st click clockwise Knob at MIN 8 Plug In Loop Detectors NOTE DO NOT HIGH NO...

Page 20: ...ly release slide gate Safety Open Device Dry Contact N O N O Telephone Entry Dry Contact N O Normal Opening Devices Dry Contact EXIT PWR ALARM POWER SOLAR IN BATTERY INPUT OPENING CLOSING CLOSING OPEN...

Page 21: ...ITION INPUTS SLIDER LIMIT SWING LIMIT OPEN ONLY NC OPEN ONLY 10K CLS ONLY NC OPEN CLS NC GND 12VDC OUT GND GND GND GND GND GND JOG RIGHT JOG LEFT TAMPER IN TAMPER NO GATE DISABLE MANUAL RELEASE KEYPAD...

Page 22: ...servicing the operator to prevent the switch from accidentally being turned ON during normal operation Plug the wire back in and turn ON the switch only while servicing the operator This can prevent...

Page 23: ...E TIMER MAGLOCK DELAY JOG BATTERY TEST INPUT ERROR BATTERY BATTERY IN USE REPLACE BATTERY LEAVE CLOSED LEAVE OPEN OPEN 1 TIME BATTERY VOLTAGE E 2 1 F RESET MANUAL RELEASE ID PLUG LINK OK MODULE PORT M...

Page 24: ...proper authorities BEFORE dropping the chain IMPROPER Dropping of Chain Vandalize Manual Disconnect switch is NOT turned ON When the chain is improperly dropped Vandalized the OPERATOR ALARM and GATE...

Page 25: ...E PORT MOTOR POSITION INPUTS SLIDER LIMIT SWING LIMIT GND OPEN ONLY NC OPEN ONLY 10K PHOTO CLS NC OPEN CLS NC GND 12VDC OUT GND GND GND GND GND GND JOG RIGHT JOG LEFT TAMPER IN TAMPER NO GATE DISABLE...

Page 26: ...RELEASE KEYPAD CARD GND GND GND MAX OPEN FIRE DEPT RADIO GND RADIO SIGNAL STRIKE CLOSE COM COM CLS ONLY 10K OPEN CLS 10K 12VDC OUT NO COM NC ERROR 24VDC OUTPUT 12VDC OUTPUT GND GND GND LOOP PWR OFF P...

Page 27: ...OWER MODE A MODE B EXIT LOOP LOOP LOOP CENTER SAFETY GATE OPEN COM GATE CLOSED MIN MATRIX III SWING SLIDE This page and the next 3 pages can help troubleshoot problems that might occur after installat...

Page 28: ...TERY IN USE LED is ON and BATTERY BACK UP MODE switch is set to Leave Open then battery may be too low and gate is kept OPEN If BATTERY IN USE LED is ON and BATTERY BACK UP MODE switch is set to OPEN...

Page 29: ...is ON CLS ONLY 10K LED is ON PHOTO CLS LED is flashing CLS ONLY 10K LED is flashing OPEN ONLY LED is ON OPEN ONLY LED is FLASHING MAX SENSE LED is ON MANUAL RELEASE RESET LED is ON but manual release...

Page 30: ...flashing Loop fault condition check if SAFETY loop wires are connected into to loop input connector properly Check if SAFETY loops are wired in series Check if loop detector is inserted properly in L...

Page 31: ...itored 4 5 6 C 1 NO1 NC1 LIGHT ON SENSITIVITY Min Max DARK ON Power Set switch to LIGHT ON 24 to 240 VAC VDC 24 to 240 1 2 N02 C2 3 Sensitivity Adjustment If the photocell does not respond to an obstr...

Page 32: ...otocell does not respond to an obstruction lower the sensitivity by turning adjustment counter clockwise OK to use 12VDC GND Installation Steps DO NOT connect to NC1 3 OPEN ONLY NC OPEN ONLY 10K OPEN...

Page 33: ...device MUST be MONITORED by the gate operator Installation Steps 1 Set switch to LIGHT ON 2 Wire 12V power to photocell 3 Wire OPEN ONLY 10K to photocell NC1 Wire GND to photocell C 1 4 Align photocel...

Page 34: ...GND OPEN ONLY NC OPEN ONLY 10K PHOTO CLS NC OPEN CLS NC GND 12VDC OUT GND GND GND GND GND GND JOG RIGHT JOG LEFT TAMPER IN TAMPER NO GATE DISABLE MANUAL RELEASE KEYPAD CARD GND GND GND MAX OPEN FIRE D...

Page 35: ...own the desired channel assignment switch until all four channel LEDs activate and the system status LED begins flashing rapidly then release the switch On the transmitter hold down the connection swi...

Page 36: ...tion device MUST be MONITORED by the gate operator Installation Steps 1 Set DIP switches 2 Remove jumper JP 5 3 Insert jumper on 4W JP 6 4 Wire 12V power to photocell VRX 5 Wire DSP board PHOTO CLS NC...

Page 37: ...protection device MUST be MONITORED by the gate operator Installation Steps 1 Set DIP switches on receiver 2 Install jumper on receiver 3 Wire Matrix III 12VDC OUT power to receiver 4 Wire PHOTO CLS...

Page 38: ...nd to an obstruction lower the sensitivity by turning adjustment counter clockwise Transmitter TX Secondary Matrix III Receiver RX Normally Closed PHOTO CLS NC Common GND Green LED Green LED NOComNC J...

Page 39: ...CK CS1 C1 BS1 BS2 NO3 C3 ATEST Com CS2 C2 C Channel 1 2 transmitters MUST be programmed by RBAND receiver See below or Miller Edge Wireless RBAND instruction sheet to program transmitters to receiver...

Page 40: ...NO NC Power NC Jog Left Jog Right External Alarm Reset Button Dry Contact Security Device PRESS to RESET ID Plug Specific for operator type REQUIRED Maglock Solenoid Lock Motion Sensor External Jog L...

Page 41: ...UTS CLOSE TIMER MAGLOCK DELAY JOG ACE ERY LEAVE CLOSED LEAVE OPEN OPEN 1 TIME LINK OK MOTOR POSITION INPUTS SLIDER LIMIT SWING LIMIT GND OPEN ONLY NC OPEN ONLY 10K PHOTO CLS NC OPEN CLS NC GND 12VDC O...

Page 42: ...Regulator 24V 10A Morning Star Handle AGM Battery Absorbant Glass Material 24V 35A Hr 2 x 12V Batteries YUASA SOLAR PACK Max Solar Pack Available for ALL SLIDE OPERATORS PRO SERIES UL325 Compliant UL...

Page 43: ...RROR 24VDC OUTPUT 12VDC OUTPUT GND GND GND LOOP LOOP PWR LOOP CENTER SAFETY OFF SINGLE OPEN ON OFF BATTERY CLOSE DUAL ON ANTI TAILGATE PUSH OPEN PULL OPEN GATE OFF 1 2 3 4 5 6 7 8 9 10 OFF 1 2 3 4 5 6...

Page 44: ...ent Loop Fault PW R LED Flashing Previous Loop Fault EDI Tel 480 968 6407 DEF LE CTO MET ER SENS RESET POWER DETECT EDI SENS LMA1800 LP OPTIONS 1 2 3 4 5 6 7 8 O N ON 1 2 3 4 5 6 7 8 5 Optim um Sen s...

Page 45: ...ATER THAN 1000 LBS LESS THAN MAX WEIGHT SWING PRO OPERATORS 33Ah 33Ah 50Ah 33Ah 50Ah 50Ah 92 97 90 59 Select proper solar panel and battery size 1 33Ah 33Ah batteries 50Ah 33Ah 50Ah 50Ah batteries bat...

Page 46: ...NOTES 38 UL 325 2018 Standard MAX 1500 PRO 2200 PRO F18 PRO Matrix III Install Version 7d...

Page 47: ...NOTES 39 UL 325 2018 Standard MAX 1500 PRO 2200 PRO F18 PRO Matrix III Install Version 7d...

Page 48: ...ETY SENSORS REQUIRED CONFORMS TO UL STD 325 MAX 1500 PRO 2200 PRO UL CLASS I II III IV MAX F18 PRO UL CLASS III IV ONLY CERTIFIED TO CAN CSA STD C22 2 NO 247 Maximum Controls LLC 10530 Lawson River Av...

Reviews: