m a x A I 4 3 0 & m a x A I 4 3 0 v T E C H N I C A L M A N U A L
38
Rev A 8/24/2020
Inhibit Regen Key
.
Inhibit Regen OFF
Inhibit Regen ON
The
Inhibit Regen Key
will work as a toggle switch that will allow the operator to postpone the regen
cycle. Default status will be OFF, once the Inhibit Regen is confirmed ON the cluster will send to ECM
the
SPN 3695
as
active
. To toggle the switch back to OFF press the
Inhibit Regen Key
to send to
ECM the
SPN 3695
as
not active
. Every change of the Status of
Inhibit Regen
will be reported
momentarily in the banner on the top of the screen. The status of the
Inhibit Regen
Key
will be
maintained through power cycles.
Regen Mode Key.
Regen Mode AUTO
Regen Mode MANUAL
The
Regen Mode Key
will work as a toggle switch that will allow the operator to change between
Automatic or Manual Def regeneration. Default status will be AUTO, once the Inhibit Regen is
confirmed MANUAL the cluster will send to ECM the
SPN 3718
as
not enabled
. To toggle the switch
back to AUTO, press the
Regen Mode Key
to send to ECM the
SPN 3718
as
enabled
. Every change
of the Status of
Regen Mode
will be reported momentarily in the banner on the top of the screen. The
status of the
Regen Mode Key
will be reset when exiting the
DPF Regeneration
screen.