12
12
For any malfunction, please contact your dealer or the Technical Service.
Never repair your device on your own. The regulations at the basis of its manufacture might break and consequently the
warranty might forfeit. The warranty forfeits also when any intervention is carried out by non-authorised staff.
CONDITIONS
The device sold is guaranteed according to the Law for possible manufacture failures. During this period, the faulty
components are replaced free, if the failure is not caused by collisions, falls, fires, short circuits or by an improper use. The
non-working device or the faulty parts are to be sent carriage free to our Company or to the authorised Technical Service.
We send the repaired components back carriage paid to the purchaser address.
INFORMATION FOR THE USERS ON THE DISPOSAL OF OUTDATED ELECTRIC AND ELECTRONIC DEVICES (FOR
PRIVATE FAMILY UNIT)
This symbol on the products and/or on the documents means that the electric and electronic products used
are not to be dispose of with generic household waste. For a correct treatment, reutilization and recycling
take these products to the collecting points, where they are accepted free. Alternatively, in some Countries
the products could be given back to the local dealer when purchasing another equivalent product. A
correct disposal of this product will allow saving precious resources and avoid possible negative effects on
the human health and on the environment. For further details, contact the local authority or the nearest
collecting point. In case of wrong disposal, penalties may be applied according to the Local Law. For the
Companies of the European Union: if you wish to dispose of electric and electronic devices, contact the dealer or the
supplier for further details.Information about disposal in Countries not belonging to the European Union. This symbol is
valid only in the European Union. If the device should be dispose of, contact the local authority or the dealer and ask for
information about a correct disposal.
WARRANTY AND TECHNICAL SERVICE
TECHNICAL SHEET
•
Dimension (cm.) 37 x 30 x 41h
•
Voltage 220-240 Volt 50-60 Hz.
•
Pressure 450 kPa
•
Resistance 1900 Watt
•
Turbine engine 1200 Watt
•
Sound Level Lpa 81,8 dBA - LWa 100,12 dBA
•
Operation temperature: +5°C / +30°C
•
Stainless steel boiler
•
Electric supply cable 6 m
•
Steam ready time 7 minutes
•
Basin capacity 5,5 l. max
•
Steam outlet 43 g/mn
•
Boiler (1,6 l.)
SAFETY
•
Thermostat
•
Thermofuse
•
Pressure switch
•
Safety valve 6 bar
•
Low voltage contol
•
Appliance complying with the low tension directive
2006/95/CE
•
Product norms EN 60335-1, EN 60335-2-2, EN 60335-2-54
•
Protection degree IP24
WARNING:
DANGER OF BURNS