113274 - 1
37
J. PREOPERATIONAL TESTS
ALL
dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test
should be
performed before the dryer is publicly used. It is possible that adjustments have changed in transit or
due to marginal location (installation) conditions.
1. Turn on electric power to the dryer.
2. Make sure the loading doors are closed and the lint drawer is closed.
3. Make sure “green” power button is in and illuminated.
4. Microprocessor controller (computer) system operational test--to start the dryer:
a. Display will read “READY.”
b. Press “D” (preprogrammed) cycle key on the keyboard (touch pad).
5. The dryer will then start (i.e., blower, tumbler, and heat).
6. The light emitting diode (L.E.D.) display will read MANUAL DRYING CYCLE D, 00:00 MIN REMAIN.
NOTE:
Press the “UP ARROW” to view the tumbler temperature at any time.
NOTE:
The dryer can be stopped at any time by pressing the “STOP/CLEAR”
key. If the
temperature is above the Cool Down set point when the “STOP/CLEAR” is pressed, the
dryer will go into a Cool Down Cycle. If the “STOP/CLEAR” key is pressed again at this
point the cycle that was in progress
will
be
canceled and returned to the “READY” state. If
the temperature is below the Cool Down set point the cycle that was in progress
will
be
canceled, and go to Wrinkle Guard.
7. When the programmed drying time has expired, the Phase 7 Non-Coin microprocessor controller (computer)
will proceed into the Cool Down Cycle (mode).
8. Once the Cool Down Cycle begins at the end of the heat cycle the L.E.D. display will read COOL DOWN
TEMP ___/___MINUTE REMAINING. At the end of the heat cycle, the dryer will shut off the heat, and
continue the fan and tumbler until the Cool Down Time, or temperature is reached.
9. Once the Cool Down Cycle is completed the Phase 7 Non-Coin microprocessor controller (computer) will
proceed into the Wrinkle Guard Cycle. The Audio Alert tone will sound for the amount set in Audio Alert
ON Time. The L.E.D. display will read “WRINKLE GUARD.” The times are fixed at 2 minutes OFF, 2
minutes ON for a max time of 99 minutes. These times are not programmable. During the ON time, the
blower (fan) and the tumbler will start to rotate (without heat for 2 minutes). The Phase 7 Non-Coin
microprocessor controller (computer) will repeat this process until the Maximum Wrinkle Guard On Time
has expired (99 minutes). The L.E.D. display will then read “CYCLE DONE” and lockout the dryer
functions until the doors are opened. It will then return to “READY.”
NOTE:
Mechanical functions of the dryer
is not
allowed during the ON time. The blower (fan)
must
be
OFF to perform mechanical functions. However the “STOP/CLEAR” key may be pressed
at any time to end the Wrinkle Guard cycle. Mechanical functions of the dryer is allowed
during the OFF time.
Summary of Contents for MAXIMD200
Page 11: ...113274 1 7 B DIMENSIONS AND COMPONENT LOCATION NON TILT GAS MODEL...
Page 12: ...8 113274 1 NON TILT STEAM MODEL...
Page 14: ...10 113274 1 1 Reassembly Instructions For Gas Dryer Shipped In Two 2 Pieces...
Page 16: ...12 113274 1 2 Reassembly Instructions For Steam Dryer Shipped In Two 2 Pieces...
Page 22: ...18 113274 1...
Page 23: ...113274 1 19...
Page 24: ...20 113274 1...
Page 64: ...Part No 113274 1 05 17 11...