background image

 

Maxey Moverley Limited, 6 Broad Ground Road, Lakeside, Redditch, Worcestershire, B98 8YP 

Web: www.cctvrepairs.com ● Email: [email protected]   

Tel: 01527 522299 ● Fax: 01527 522588 

    

                                                                                                          Issue 1.1

 

| Page 4

 

 

Quick Reference Guide 

Vista PowerDome

 

3.

 

Addressing 

The receiver card mounted on the Power Domes pan/tilt contains a multi position DIP switch, as 
seen below. Use the switch to assign a camera number to the Power Dome. 

 

 

 

 

 

 

 

 

 

 

 

3.1

 

 Dip Switch Positions & Equivalent Values 

To program the receiver’s site number on the DIP switch use the table below:  

Dip Switch Position Number 

10 

11 

12 

Equivalent Value 

16 

32 

64 

128 

256 

512 

 

If you use the PowerDome with coaxial UTC telemetry, we recommend that you set the address 
especially if you plan to add a VPD-ALM16 alarm module. 
 
If you use RS485 directly from a Vista NPX/KBD/J3De or VPD-KBD keyboard that is also controlling 
multiple Vista Triplex Columbus digital recorders or VDC1604 matrix units, address domes attached 
to the units as follows: 
 

 

Unit with BaxNet address 1: 1 through 16 

 

Unit with BaxNet address 2: 17 through 32 

 

Unit with BaxNet address 3: 33 through 48 

 

Unit with BaxNet address 4: 49 through 64 
 

For units with any other BaxNet address, domes should be numbered 1 through 16 and you should 
use only one keyboard.  
 
When you use UTC control, each receiver needs to tune to the transmitter. Select each dome in turn, 
and pan left and right until the dome moves. This should take about 5 to 10 seconds. 