41
QM00152-1
PJLink command (continued)
Commands
Control Description
Parameter or Response
ERST ?
Error Status inquiry
1st byte: Refers to Fan error; one of 0 to 2
2nd byte: Refers to Lamp error; one of 0 to 2
3rd byte: Refers to Temptrature error; one of 0 to 2
4th byte: Refers to Cover error; one of 0 to 2
5th byte: Refers to Filter error; one of 0 to 2
6th byte: Refers to Other error; one of 0 to 2
The mearning of 0 to 2 is as given below
0 = Error is not detected;
1 = Warning; 2 = Error
LAMP ?
Lamp Status inquiry
1st number (digits 1 to 5): Lamp Time
2nd number : 0 = Lamp off, 1 = Lamp on
INST ?
Input Source List inquiry 11 12 21 22 23 31 33 41 51 52
NAME ?
Projector Name inquiry
Responds with the name set in the item
PROJECTOR NAME of the NETWORK menu
INF1 ?
Brand Name inquiry
MAXELL
INF2 ?
Model Name inquiry
MC-X8170
MC-WX8265
MC-WU8460
INFO ?
Other Information inquiry Responds with the factory information and so
on
CLSS ?
Class Information inquiry 1
NOTE
• The password used in PJLink
TM
is the same as the password set
in the Web Control. To use PJLink
TM
without authentication, do not set any
password in Web Browser Control.
)RUVSHFL¿FDWLRQVRI3-/LQN
TM
, see the web site of the Japan Business
Machine and Information System Industries Association.
URL: http://pjlink.jbmia.or.jp/